MAINTENANCE
SECTION 5
Page 78
CMD-4081877 / 90-865861040 MARCH 2004
0161.02
Corrosion Protection
Whenever two or more dissimilar metals are submerged in a conductive solution, such as
saltwater, polluted water or water with a high mineral content, a chemical reaction takes
place causing electrical current to flow between metals. The electrical current flow causes
the metal that is most chemically active, or anodic, to erode. This is known as galvanic
corrosion and, if not controlled, it will in time cause the need for replacement of power
package components exposed to water. Refer to the
Marine Corrosion Protection Guide
(90-88181301).
CE550
Antifouling Paints
In some areas it may be advisable to paint the bottom of the boat to help prevent marine
growth. Contact your authorized Cummins MerCruiser Diesel dealer / distributor for
recommendations for your boat.
00000
Internal Components
Sacrificial anode locations:
•
Starboard, aft-end of the heat exchanger / fluid cooler.
•
Top of the aftercooler end cover.
REMOVAL
1. Allow the engine to cool.
2. Remove anode plugs and sacrificial anodes.
80059
b
c
a
c
a -
Heat exchanger
b -
Aftercooler end cover
c -
Anode plug and sacrificial anode
Summary of Contents for 2.8 EI 200
Page 1: ...2004 Mercury Marine 2 8 EI 200 Diesel Inboard Models CMD 4081877 90 865861040 304...
Page 28: ...GETTING TO KNOW YOUR POWER PACKAGE SECTION 2 Page 20 CMD 4081877 90 865861040 MARCH 2004 NOTES...
Page 56: ...SPECIFICATIONS SECTION 4 Page 48 CMD 4081877 90 865861040 MARCH 2004 NOTES...
Page 96: ...MAINTENANCE SECTION 5 Page 88 CMD 4081877 90 865861040 MARCH 2004 NOTES...
Page 104: ...STORAGE AND RECOMMISSIONING SECTION 6 Page 96 CMD 4081877 90 865861040 MARCH 2004 NOTES...