COLD WEATHER OR EXTENDED STORAGE
eng
119
14.Before launching the boat, pull up on the manual release
valve. Verify that the green indicators are no longer
extended.
a -
Manual pressure release valve
b -
Threaded cap for air connection
c -
Green indicators
15.Open the seacock, if equipped, or unplug and reconnect the
water inlet hose prior to operating the engine.
BOAT OUT OF THE WATER
NOTE: This procedure is written for the air pump that is attached
to the engine. However, any air source can be used.
1. Place the boat on a level surface and ensure that the boat is
level.
2. Obtain the air pump.
3. Ensure that the lever on top of the pump is flush with the
handle (horizontal).
4. Install the air pump on the air connection.
5. Pull the lever on the air pump (vertical) to seal the pump to
the air connection.
a
b
c
50399