9. TERMS OF GUARANTEE ___________________________________________  

 
 
1.  The  Manufacturer  provides  a  guarantee  for  the  delivered  product  for  12  months  from  the  date  of 

issuing the invoice, unless the guarantee period is specified in a separate contract. 

2.  Any faults revealed during the guarantee period, which prevent correct operation of the product, shall 

be  rectified  within  21  days  from  the  date  of  reporting,  unless  the  time  for  rectifying  the  faults  is 
specified in a separate contract. 

3.  The guarantee is extended by the period from reporting the fault to finishing the guarantee repair. 
4.  If  any  faults  preventing  further  correct  operation  of  the  product  are  found  in  the  product,  the 

Manufacturer  shall  replace  the  faulty  product  with  a  product  of  full  value  with  no  financial 
consequences to the purchaser. 

5.  The  guarantee  does  not  include  the  operations  performed  by  the  purchaser/user,  specified  in  the 

Documentation. 

6.  The Manufacturer is absolved from the guarantee and any obligations resulting from the guarantee if: 

a)  the product has mechanical damage created due to: 

- improper transport or unloading using own means of the purchaser 
- improper installation using own forces of the purchaser  
- improper operating of the product 

b)  faults arise in result of improper storage of the product 
c)  the purchaser/user has introduced structural modifications on their own  
d)  installation of the product has been performed by the purchaser on their own, not in accordance 

with the Documentation 

e)  faults arise in result of maintenance of the product not in accordance with the Documentation  
f)  a rating plate of the product is removed 

7.  In the complaint procedure for the product, the Manufacturer deducts the equivalent of the elements 

missing or damaged through the purchaser's/user's fault and the cost of their replacement. 

 

Summary of Contents for mcr PL1

Page 1: ... 08 GDAŃSK 2008 ul Grzegorza z Sanoka 2 80 408 Gdańsk tel 48 58 341 42 45 tel fax 0 58 341 39 85 TECHNICAL AND OPERATIONAL DOCUMENTATION Overpressure bleed damper of mcr PL1 type FIRE VENTILATION SYSTEMS DEPARTMENT ...

Page 2: ... THE DOCUMENTATION 3 3 PURPOSE OF THE DEVICE 3 4 CONSTRUCTION AND PRINCIPLE OF OPERATION OF THE DEVICE 3 5 DESIGNATION OF THE DEVICE 6 6 INSTALLATION OF THE DEVICE 6 6 1 PRE INSTALLATION INSPECTION 6 6 2 INSTALLATION OPENING 6 6 3 EMBEDDING 7 6 4 ELECTRICAL CONNECTIONS 8 7 TRANSPORT AND STORAGE CONDITIONS 8 8 MAINTENANCE AND SERVICE 8 9 TERMS OF GUARANTEE 9 ...

Page 3: ...r partition thus operating as so called safety valves that prevent the increase of pressure above a set value e g in a protected staircase The devices meet the requirements of the PN EN 12101 6 standard Fire Resistance ___________________________________________________________________ The device does not feature fire resistance as it is not required for its correct operation Execution Versions __...

Page 4: ...uitable flow of an air stream Driving and Tripping Systems ____________________________________________________ The driving system of mcr PL1 dampers is made of suitably selected steel weights that are mounted on blades of the device Dimensions _______________________________________________________________________ Mcr PL1 dampers are manufactured in the following dimensions Height Breadth B mm H ...

Page 5: ...ssembly sets are made of a suitable number of single dampers of the basic type as well as flat bars and connecting elements Basic dimensions of mcr PL1 dampers have been presented on the drawing below 3 2 4 1 Technical characteristics 50 55 60 65 70 75 80 85 90 4000 5000 6000 7000 8000 9000 10000 11000 12000 13000 discharge V m3 h pressure P Pa PL500x500 PL600x600 PL750x750 PL400x400 NOTE Net dime...

Page 6: ...TION INSPECTION __________________________________________ Each damper is inspected before packing and shipment by the manufacturer After unpacking at the recipient perform visual inspection to check if the casing has not been deformed and whether the damper has not been damaged during transport 6 2 INSTALLATION OPENING _________________________________________________ The minimum size of the open...

Page 7: ...mper with protective film or other covering material before installation until the masonry and finishing work is completed After the concrete mortar sets remove the brackets and open individual blades of the damper manually to check if they operate correctly Connection of the embedded damper to the ventilation duct must be executed coaxially During installation of the damper in the partition a dam...

Page 8: ...r each transport each damper should be visually inspected The damper must not be hit or dropped During handling and installation attention should be paid to the damper baffle The dampers should be stacked in no more than 2 layers vertically in closed rooms ensuring protection against external weather conditions In the case of storing of the dampers on the ground they should be placed on protective...

Page 9: ...ull value with no financial consequences to the purchaser 5 The guarantee does not include the operations performed by the purchaser user specified in the Documentation 6 The Manufacturer is absolved from the guarantee and any obligations resulting from the guarantee if a the product has mechanical damage created due to improper transport or unloading using own means of the purchaser improper inst...

Reviews: