Installation, Operation and Maintenance Instructions
Weather-proof louvre, horizontal,
WSG-H3 for flat roof
1 General ....................................................................................................................................................................2
2 Type overview of horizontal weather-proof louvres ..............................................................................................3
2.1 WSG-H3-Fu
(bottom flange without duct connection / drainage over-roof)
2.2 WSG-H3-Fu-KA
(bottom flange with duct connection / drainage over-roof)
2.3 WSG-H3-Fo
(top flange without duct connection / internal drainage by pipes)
2.4 WSG-H3-Fo-KA
(top flange with duct connection / internal drainage by pipes)
3 Mounting frame for horizontal weather-proof louvres in flat roof design (optional) ...........................................4
4 Roof systems ............................................................................................................................................................4
4.1 Warm roof (classic flat roof construction)
4.2 Insulation, wet-side (inverted roof)
5 Installation instructions..........................................................................................................................................5
5.1 General.............................................................................................................................................................5
5.2 Installation in warm roof construction ........................................................................................................... 7
a) WSG-H3-Fu .................................................................................................................................................. 7
(bottom flange without duct connection / drainage over-roof)
b) WSG-H3-Fu-KA ...........................................................................................................................................8
(bottom flange with duct connection / drainage over-roof)
c) WSG-H3-Fo ..................................................................................................................................................9
(top flange without duct connection / internal drainage by pipes)
d) WSG-H3-Fo-KA .........................................................................................................................................10
(top flange with duct connection / internal drainage by pipes)
5.3 Installation in inverted roof construction, wet-side insulation......................................................................11
a) WSG-H3-Fu ..................................................................................................................................................11
(bottom flange without duct connection / drainage over-roof)
b) WSG-H3-Fu-KA ..........................................................................................................................................12
(bottom flange with duct connection / drainage over-roof)
c) WSG-H3-Fo .................................................................................................................................................13
(top flange without duct connection / internal drainage by pipes)
d) WSG-H3-Fo-KA ......................................................................................................................................... 14
(top flange with duct connection / internal drainage by pipes)
6 Transport / handling ...............................................................................................................................................15
7 Maintenance ..........................................................................................................................................................16
8 Exemption from liability ........................................................................................................................................16
LUCOMA AG,
Weekendweg 5, CH-3646 Einigen, Switzerland
Tel: +41 33 655 00 44, Fax: +41 33 655 00 45, www.lucoma.com, in[email protected]