Mains Connection Schemes.
1
Country
Local
frequency
Local voltage
(domestic applications)
Phase L1
Phase L2
Phase L3
Neutral
1-ph 3-ph
Albania
50 Hz
230 / 400 V
L1
L2
L3
N
x
Argentina
50 Hz
220 / 380 V
L1
L2
L3
N
x
Australia
50 Hz
230 / 400 V
L1
N
x
Azerbaijan
50 Hz
230 / 400 V
L1
L2
L3
N
x
Bahrain
50 Hz
230 / 400 V
L1
L2
L3
N
x
Bosnia and Herzegovina
50 Hz
230 / 400 V
L1
L2
L3
N
x
Brazil
60 Hz
110 / 220 V
L1
L2
x
220 / 400 V
L1
N
x
127 / 220 V
L1
L2
x
220 / 380 V
L1
L2
L3
N
x
Cayman Islands
60 Hz
120 / 240 V
L1
L2
x
Chile
50 Hz
220 / 380 V
L1
L2
L3
N
x
China
50 Hz
127 / 220 V
L1
L2
x
220 / 380 V
L1
L2
L3
N
x
Colombia
60 Hz
110 / 220 V
L1
L2
x
Eurasian Customs Union
(Belarus, Kazakhstan, Russia)
50 Hz
230 / 400 V
L1
L2
L3
N
x
French Polynesia (Tahiti)
60 Hz
220 V
L1
N
x
Hong Kong
50 Hz
220 / 380 V
L1
L2
L3
N
x
India
50 Hz
220 / 380 V
L1
L2
L3
N
x
230 / 400 V
240 / 415 V
Indonesia
50 Hz
127 / 220 V
L1
L2
x
220 / 380 V
L1
L2
L3
N
x
Iran
50 Hz
230 / 400 V
L1
L2
L3
N
x
Israel
50 Hz
230 / 400 V
L1
L2
L3
N
x
Jamaica
50 Hz
110 / 220 V
L1
L2
x
Japan
50 / 60 Hz
200 V
L1
L2
x
Jordan
50 Hz
220 / 380 V
L1
L2
L3
N
x
Kuwait
50 Hz
240 / 415 V
L1
L2
L3
N
x
Laos
50 Hz
230 / 400 V
L1
L2
L3
N
x
Lebanon
50 Hz
220 / 380 V
L1
L2
L3
N
x
Malaysia
50 Hz
240 / 415 V
L1
L2
L3
N
x
Macedonia
50 Hz
230 / 400 V
L1
L2
L3
N
x
Mauritius
50 Hz
230 / 400 V
L1
L2
L3
N
x
2
Country
Local
frequency
Local voltage
(domestic applications)
Phase L1
Phase L2
Phase L3
Neutral
1-ph 3-ph
New Zealand
50 Hz
230 / 400 V
L1
N
x
Oman
50 Hz
220 / 380 V
L1
L2
L3
N
x
240 / 415 V
Pakistan
50 Hz
230 / 400 V
L1
L2
L3
N
x
Panama
60 Hz
220 V
L1
L2
x
Qatar
50 Hz
240 / 415 V
L1
L2
L3
N
x
Saudi Arabia
60 Hz
127 / 220 V
L1
L2
x
220 / 380 V
L1
N
x
Singapore
50 Hz
230 / 400 V
L1
N
x
South Africa
50 Hz
230 / 400 V
L1
L2
L3
N
x
South Korea
60 Hz
220 / 380 V
L1
N
x
Sri Lanka
50 Hz
230 / 400 V
L1
L2
L3
N
x
Taiwan
60 Hz
110 / 220 V
L1
L2
x
220 / 440 V
L1
N
x
Thailand
50 Hz
220 / 380 V
L1
L2
L3
N
x
Ukraine
50 Hz
230 / 400 V
L1
L2
L3
N
x
United Arab Emirates
50 Hz
220 / 380 V
L1
L2
L3
N
x
240 / 415 V
Uruguay
50 Hz
230 / 400 V
L1
L2
L3
N
x
Vietnam
50 Hz
127 / 220 V
L1
L2
x
220 / 380 V
L1
L2
L3
N
x
Region
Country
Local
frequency
Local voltage
(domestic applications)
Phase L1
Phase L2
Phase L3
Neutral
1-ph 3-ph
Europe
(without Norway and UK)
50 Hz
230 / 400 V
L1
N
x
L1
L2
L3
N
x
Norway
50 Hz
110 V
L1
N
x
230 / 400 V
L1
L2
L3
N
x
UK
50 Hz
240 / 415 V
L1
N
x