39
G55.00-3169-00
Introduction of the New Unimog Generation | Model Series 405
Overview
Hydr
aulic com
ponents
b
Note
All of the aforementioned volumetric flow rate and
pressure specifications are maximum values, which
are only available at the corresponding engine speed
and may not be available permanently.
Power hydraulics (circuit III and IV)
The power hydraulics allow rotating consumers to be powe-
red (e.g. cutting roller, wood chipper etc.). Both circuits are
designed as open circuits with a maximum volumetric flow
rate of 125 l/min each at a maximum of 280 bar. Code HL4
includes one circuit while code HL5 includes two power hyd-
raulics circuits.
•
The power hydraulics are located in the platform interme-
diate frame and can be quickly removed if they are not
required e.g. during winter service operations in order to
increase the payload. As a result, the connections are no
longer in the vehicle center but at the vehicle rear.
•
In addition to the rear connections, front connections are
also possible for both circuits (including simultaneously)
with code H93 and H94.
Overview of hydraulic components
– This printout will not be recorded by the update service. Status: 03 / 2013 –