background image

 

16 

 

REPLACEMENT PARTS 

X-62  GAS  LOG  INSERT

 

 

WARNING:  Use only authorized parts and materials obtained from Johnson Gas Appliance when 

replacing any defective or damaged parts.  DO NOT substitute parts and materials obtained from 
other manufacturers. 

 

PART NUMBER 

ITEM 

 

 

35-01-00486 

LOG SET 

35-01-00240 

COALS 

HA-74-00028 

VALVE ASSEMBLY 

05-02-00331 

VALVE 

05-02-00330 

VALVE SOLENOID 

HA-74-00003 

BURNER ASSEMBLY 

05-04-00045 

PILOT ASSEMBLY 

65-14-00025 

NATURAL GAS ORIFICE (# 25) 

65-14-00043 

L.P. GAS ORIFICE (# 43) 

15-02-00068 

BLOWER ASSEMBLY 

10-01-00047 

RHEOSTAT KNOB 

HA-74-00053 

DAMPER SWITCH ASSEMBLY 

65-06-01183 

REMOTE CONTROL 

HA-74-00042 

BRICK CLIP (optional) 

AA-11-00927 

CLINKER STYLE BRICK KIT (optional) 

AA-11-00944 

RAPIDS ROCK STYLE BRICK KIT (optional) 

AA-11-00945 

FIRED BRICK STYLE BRICK KIT (optional) 

 

Summary of Contents for X-62

Page 1: ...il QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ Ne pas tenter d allumer d appareil Ne touchez aucun interrupteur Ne pas vous servir des t l phones se trouvant dans le b timent o vous vous trouvez Appelez...

Page 2: ...S 7 W C 6 5 W C MIN 10 5 W C MAX L P GAS 11 W C 12 2 W C MIN 13 W C MAX GAS INLET 3 8 N P T INTERTEK TESTED TO AGA ANSI STANDARD Z21 60 2003 CAN CGA 2 26 M03 CGA CR93 0004 This appliance may be used w...

Page 3: ...outside in accordance with the latest edition of the Natural Fuel Gas Code Do not connect this appliance to a chimney flue serving a separate solid fuel burning appliance The X 62 is a decorative gas...

Page 4: ...E 4 V A LV E P R E S S U R E T A P F IT T IN G F O R T E S T IN G M A N IF O LD P R E S S U R E B LO W E R A D JU S T M E N T D A M P E R O P E N N A T L P C O N V E R S IO N S T E M R E D R E D B LA...

Page 5: ...uld not be installed in any fireplace that is normally subject to severe downdrafts Downdraft conditions exist if when starting a wood fire it is difficult to establish a good upward draw i e smoke an...

Page 6: ...ies and codes NEVER use plastic pipe GAS PRESSURE REQUIREMENTS A MAJOR CAUSE OF OPERATING PROBLEMS WITH GAS APPLIANCES IS IMPROPER GAS PRESSURE Such problems as changes in flame color or configuration...

Page 7: ...uired by local codes or if the supply gas pressures exceed PSIG 3 5KPA and a regulator of sufficient capacity b Flex hose used to connect the appliance must have brass to brass fittings c The gas pres...

Page 8: ...to L P Gas remove the rubber cap that covers the valve conversion stem Depress the stem and rotate it clockwise until it locks in place in the depressed position Replace the rubber cap See Fig 4 page...

Page 9: ...ls Spread the coals on top of the burner to produce a glowing ember effect and also around the base of the burner to conceal it see Fig 6 DO NOT spread any coals over the slots at the front of the app...

Page 10: ...f the flame improves Tighten the nut of the air shutter Replace the front vent plate and screw it to the firebox floor NOTE If sooting persists turn off the appliance and call your Mendota dealer 19 I...

Page 11: ...of the grate bar as shown Make sure that the log is tight against the back of the firebox Place the notch on log 2 over the left grate bar Slide log 2 back against the tabs that are located on the to...

Page 12: ...osition pinned log 6 so that its left end is in contact with the right end of log 2 Log 3 rests on log 2 with its right end against the grate bar as shown in the circled area Log 5 rests in the notche...

Page 13: ...nuously until it is turned off Press the HI button on the remote to operate the appliance with maximum flame and heat Press the LOW button on the remote to operate the appliance with minimum flame and...

Page 14: ...The gas supply is turned off C The batteries in the remote and or receiver need replacing D The remote needs to be synchronized with the receiver E The pilot assembly is dirty F Any other cause A Mak...

Page 15: ...valve and the air shutter on the venturi Use a brush or wire to clean the inlet of the venturi Clean foreign matter and carbon deposits from the burner pan and burner tiles Check to see that the burne...

Page 16: ...COALS HA 74 00028 VALVE ASSEMBLY 05 02 00331 VALVE 05 02 00330 VALVE SOLENOID HA 74 00003 BURNER ASSEMBLY 05 04 00045 PILOT ASSEMBLY 65 14 00025 NATURAL GAS ORIFICE 25 65 14 00043 L P GAS ORIFICE 43...

Page 17: ...the back of the firebox and the brick pattern must face forward NOTE The rear brick panel is held in place by the left and right brick panels DO NOT let the rear panel fall forward before the side pan...

Page 18: ...18 NOTES...

Page 19: ..._____________________________ DATE INSTALLED __________________________________ REF X 62 INSTALLATION MANUAL THE EXISTING FIREPLACE CHIMNEY MEET ALL OF THE REQUIREMENTS see page 5 THE GAS SUPPLY MEETS...

Page 20: ...20...

Page 21: ...nty does not cover glass or log breakage Cracks in the burner ceramic plaques is normal and not covered under warranty unless pieces of the ceramic are missing Mendota has the right to investigate and...

Page 22: ...22 Johnson Gas Appliance Company 520 E Avenue N W Cedar Rapids IA 52405 Mendota Hearth Division 85 03 00738 C...