MANTEL CLEARANCES
Mantel Clearances for this fireplace may be measured from
the top of the convection air opening
or
the floor level of
this fireplace
.
The location that is referenced normally to measure mantel clearances is the Top of the Convection Air Opening.
For ease, however, measure up from the floor level of this fireplace. The chart and diagram, in this page, provide
all the reference dimensional information necessary in determining the distance a combustible mantel may pro-
trude out from the face surface of this fireplace. The Chart, at left, shows the Distance from Fireplace Face the
combustible mantel may protrude outward at a Distance up From Floor Level of this Fireplace.
If you prefer to take measurements from the Top
of the Convection Air Opening, note that the
Top of the convection air opening is 35
inches up from the floor level of this fire-
place.
WARNING:
Make proper use of this chart.
Do not compromise the specifications con-
tained in this chart.
Failure to adhere to proper clearances re-
quired to combustibles may cause spontaneous com-
bustion of the mantel and may result in property damage,
personal injury or loss of life.
Figure 2: Mantel Clearances