Backup DC Power Inlet Port Installation
INSTALLATION:
It is important that you install the supplied harness, outlet box and cover plate on the left side of this appliance.
The DC Power Inlet harness is 6 feet long, allowing installation of the single gang box up to 5 feet to the left of this appliance.
Instal
l the single gang box at a maximum height of 18” to the center of the box or match the mounting height of this single gang
box with the height of other AC outlets that are installed in the same room as this appliance.
WARNING: DO NOT STAPLE the 6’
DC Power Inlet Harness to the wall studs.
COVER PLATES
: Two cover plates are supplied and are White and Beige in color. If the home décor requires a different color
other than the two supplied colors, obtain one from a local hardware store. Make certain that the cover you obtain is the same
dimensions as the ones supplied with this fireplace.
DECAL INSTALLATION
: A notification decal (label) is supplied with this fireplace that aids in identifying the DC Power Inlet.
Attach this label to cover plate once installation is complete and verified.
INSTRUCT HOMEOWNER
: Demonstrate to the homeowner how to attach the backup DC power pack during power outages.
Instruct homeowner to retain the DC battery pack and the connecting harness in a safe and secure place for use during power
outages
Figure 3-26 Backup DC Power Junction Box Installation
Figure 3-27 BACKUP DC POWER
INLET
Figure 3-28 DC Backup Power Connection