85-03-01194
FV48
Page
74
Remote Control Functions
NOTE
: You will hear an audible beep once every
time a remote-control button is pressed,
signaling that the command has been received.
If you do not hear the beep, press the button
again.
Locate the four function buttons on the remote
control:
1.
On/Off Button
: This button turns the
fireplace on or off. When this button is
pressed and the system is off, the pilot
will ignite. After pilot ignition, the pilot
will light the main burners. Refer to IPI and CPI Modes in this manual for pilot ignition.
2.
Thermostat Button
: This button will allow the selection of three modes: Manual, Normal Thermostat, and Smart
Thermostat.
a.
Manual (Off)
: In this mode, the fireplace can be turned on, regardless of the room temperature. The actual room
temperature has no effect in this mode. All other functions such as fan speed control, flame height control,
secondary burner on/off control and accent light intensity controls are manually controlled.
WARNING: Do not leave this appliance burning and unattended for long periods in the manual(off) mode.
Leaving the appliance burning in manual (off) mode for long periods can lead to overheating of the living
space which can negatively affect plants, animals, infants and vulnerable people.
Note: In Manual Mode, t he fireplace will automatically shut off after 12 hours of continuous use. In Normal
Thermostat and Smart Thermostat modes, if the fireplace does not receive a prompt from the remote -
control transmitter for 60 minutes, the fireplace will automatically shut off. This can occur if the remote
control is moved to another room or if the remote batteries are very we ak.
b.
Normal Thermostat (On)
: In this mode, the
fireplace will turn itself on and off, depending
on the temperature you set. When you set the
fireplace thermostat, the fireplace will stay
functioning until the room temperature
increases 1
o
F above the set thermostat
temperature. To increase the thermostat
temperature, press the up button until the
desired temperature is displayed in the thermostat temperature window. The fan will turn on five minutes after
fireplace startup and will turn off 12-1/2 minutes after the flames turn off, in this mode. The flame height can be
adjusted while the fireplace is functioning, fan speed can be adjusted after five minutes of startup. Rear burner can
be turned on or off at any time after startup. The accent light can be adjusted any time after startup.
c.
Smart Thermostat (Smart)
: In this mode, room temperature is maintained and flame height adjusts automatically to
provide continual, efficient heat. All other functions of the normal thermostat mode, except the flame height
adjustment, are allowed. Manual flame height adjustment is not allowed in this mode. The Smart Thermostat
function adjusts the flame height in accordance to the difference between the set point temperature and the actual
room temperature. As the room temperature gets closer to the set point temperature, the Smart Thermostat
automatically modulates the flame down.
3.
Up/Down Button:
This button is used to increase or decrease the thermostat temperature, flame height, fan speed, and
accent light intensity. This also controls the rear burner on/off
.
4.
Mode Selection Button:
This button is used to toggle between the various function icons: flame height, fan speed,
accent light, and rear burner.
Figure 5-1 Remote Control Buttons
Figure 5-2 Display Modes