REMOTE TRANSMITTER OPERATING INSTRUCTIONS  

TO TURN ON THE APPLIANCE

1.  Press the ON/OFF button.  The transmitter display will show all active icons on the screen.

 

 

2.  Select the Thermostat Mode by pressing the Thermostat Key: OFF (meaning Manual 

Mode), ON (meaning normal Thermostat) or Smart (meaning Smart Mode). 
a.  In OFF (Manual Mode), the appliance will ignite and start on HI. 
b.  In ON (Normal Thermostat Mode), the appliance will only ignite if the Set Temperature 

is greater than the Room Temperature. 

c.  In SMART (Smart Mode), the appliance will only ignite if the Set Temperature is greater 

than the Room Temperature. 

TO TURN OFF THE APPLIANCE

, press the ON/OFF button. 

 

MODE

  KEY: 

Pressing  the  MODE  KEY  toggles  between  the 

various  available  functions:  Flame  Height, Fan Speed, Accent 
Light Dimmer and Secondary Burner On/Off. 

 

Flame Height: 

6 flame height Levels are available. While the Flame Height 

Icon  is  displayed,  pressing  the  Up  or  Down  button  once  will 
increase or decrease the flame height by 1 of 6 increments. If 
the  flame  height  is  at  Level  1  and  the  Down  button  is 
pressed,  all  burners  will  turn  OFF.  If  in  IPI  mode,  the  pilot 
light  will  also  extinguish.  If  in  Standing  Pilot  Mode,  the  pilot 
light  will  remain  ON.  Note:  If  in  SMART  model,  the  flame 
height  function  is  not  available  for  manual  adjustment.  In 

SMART mode, the flame height regulates automatically.  

 

 

Fan  Speed  Control: 

The  fan  speed  can  be  adjusted  through  six  (6)  speeds  and 

OFF.  To activate this function, press the MODE Key to index to the fan 
control icon. Use the UP/Down Arrow Key to turn ON, OFF or adjust the 
fan speed. A sin

gle “beep” will confirm reception of the command. Once 

you set the desired fan control, the system will remember your selected 
fan speed until you manually change it. 

 

 

 

Accent-Light  Dimmer: 

This  function  controls  the  Mendota  Accent  Light  functions. 

Pressing the UP key in this mode will TURN ON the Accent Light and 
allow  you  to  control  the  brightness  of  the  Accent  Light  in  6  steps.  A 
single “beep” will confirm reception of the command.  Once you set the 
desired  light  brightness,  the  system  will  remember  your  selected 
brightness level until you manually change it. 
 

 

 

Secondary  Burner: 

This  function  controls  the  Secondary  Burner’s  ON/OFF  fea-

ture. Pressing the UP Key in this mode will TURN ON the Second-
ary  Burner  and  Pressing  the  DOWN  Key  will  TURN  OFF  the  Sec-
ondary  Burner.  The  flame  level  will  not  change  when  you  turn  the 
Secondary  Burner  On  or  Off.  The flame level can only be changed 
in the Flame Level mode. 

Summary of Contents for FV41-PF2

Page 1: ...rvice must be performed by a qualified installer service agency or the gas suppli er WARNING Do NOT use this appliance if any part has been under water Immediately call a qualified service technician...

Page 2: ...ilis uniquement avec les types de gas indiqu s sur la plaque signal tique Ne pas l utiliser avec d autres gas sauf si un kitde conversion certifi est install READ and UNDERSTAND all instructions caref...

Page 3: ...stem is disassembled for any reason reinstall per the instructions provided for the initial installation The vent system assembly for this fireplace must be periodically examined by a qualified servic...

Page 4: ...FIRST TIME PILOT LIGHTING INSTRUCTIONS 11 INITIALIZING THE REMOTE CONTROL SYSTEM 11 Synchronizing Receiver and Transmitter 11 IPI STANDING PILOT SYSTEM INFORMATION 12 CPI Standing Pilot Mode If set to...

Page 5: ...NOT BE PLACED on or near the appliance Children and adults should be ALERTED to the hazards of high surface temperature and should STAY AWAY to avoid burns or clothing ignition Young children should...

Page 6: ...UNIT BOTTOM TO ENCLOSURE CEILING 50in 127 cm VENT PIPE BOTTOM TO COMBUSTIBLES 1in 25mm UNIT BOTTOM TO ROOM CEILING 72 in 1829 mm 8 MANTLE ABOVE DISCHARGE AIR OPENING 18 in 457 mm MINIMUM COMBUSTIBLE...

Page 7: ...t annually by a professional service person More frequent cleaning may be required due to excessive lint from carpeting bedding material carbon build up etc It is imperative that control compart ments...

Page 8: ...until the room temperature in creases 1 o F above the Set Point Temperature To increase the Set Point Temperature Press the UP button until the desired temperature is displayed in the SET POINT TEMPE...

Page 9: ...so extinguish If in Standing Pilot Mode the pilot light will remain ON Note If in SMART model the flame height function is not available for manual adjustment In SMART mode the flame height regulates...

Page 10: ...ries used the number of ignitions of the appliance the number of changes to the room thermostat set point etc When the Transmitter bat teries are low a Battery Icon will appear on the LCD display of t...

Page 11: ...the pilot is burning steadily 7 Once the pilot flame is lit and well established close glass door WARNING NEVER IGNITE MAIN BURNERS WITH GLASS DOOR REMOVED OR OPEN Doing so will lead to damage to pilo...

Page 12: ...n the CPI Standing Pilot mode to allow the pilot light to remain on indefinitely by setting the Remote Transmitter to CPI mode If the remote transmitter is set to the IPI Intermittent Pilot mode the p...

Page 13: ...O REPLACE DOOR 1 With the Glass Door at a sharp angle to the firebox line up the three bottom tabs in glass frame bottom with slots in glass clips on firebox bottom Insert tabs into slots and center t...

Page 14: ...P a g e FV 41 LOG SET INSTALLATION INSTRUCTIONS FOLLOW EACH STEP DEPICTED IN THE DIAGRAMS BELOW TO INSTALL THE LOG SET CAUTION LOGS ARE FRAGILE HANDLE LOG PIECES WITH CARE FV 41 LOG SET PARTS IDENTIFI...

Page 15: ...85 03 00890 15 P a g e...

Page 16: ...85 03 00890 16 P a g e...

Page 17: ...85 03 00890 17 P a g e...

Page 18: ...85 03 00890 18 P a g e...

Page 19: ...85 03 00890 19 P a g e...

Page 20: ...85 03 00890 20 P a g e...

Page 21: ...85 03 00890 21 P a g e...

Page 22: ...85 03 00890 22 P a g e PLACE SMALL COALS ON TOP OF FLOOR BRICK PANELS AND CLOSE TO GRATE BOTTOM TO SIMULATE A COAL BED...

Page 23: ...ing the blower on increases the overall efficiency of this fireplace and aids in distributing and circulating heat to the room this fireplace is installed in BLOWER OPERATION The remote control system...

Page 24: ...horizontal and vent runs 1000 sealant must be used on inner joints at adjustable pipe sections CHECK FOR PROPER CLEARANCES TO COMBUSTIBLES VENT LOCATIONS Per Manual INSTALL PROPER SIZE GAS LINES CHEC...

Page 25: ...85 03 00890 25 P a g e TAPE SHUT JOHNSON GAS APPLIANCE COMPANY 520 E AVENUE N W CEDAR RAPIDS IA 52405 POSTAGE NEEDED...

Page 26: ...purchases that have not received prior written approval from Mendota NOTE Minor warping of certain parts or discoloration is normal and is not a defect covered by this warranty Major warping of parts...

Page 27: ...85 03 00890 27 P a g e Johnson Gas Appliance Company 520 E Avenue N W Cedar Rapids IA 52405 Mendota Hearth Division WEBPAGE www johnsongas com or www mendotahearth com...

Reviews: