background image

85-03-00890                        7 | P a g e  

 

 

CONGRATULATIONS 

You are the owner of a world-class heat producing gas direct vent sealed combustion fireplace. 

This elegant, highly efficient Fireplace will be a constant source of comfort and fascination.  It will be the focal point of 
beauty and interest in your home. 

The Mendota Gas Fireplace is a true heating appliance incorporating the traditional aesthetics of fireplace fire viewing with 
the controllability and fuel efficiency of a home gas furnace. Of particular interest is the low fuel consumption and brilliant 
fire viewing afforded by the realistic Premium Fiber wood fire-like combustion system. 

Carefully read the following instructions prior to actual installation.  Proper Mendota Gas Fireplace installation and opera-
tion will give you years of safe, trouble free comfort and enjoyment. 
If you have any questions regarding installation or operation of your Mendota Fireplace please contact your local dealer. 

...CAUTION... 

Due to high temperatures, the Fireplace should be located out of traffic and away from furniture and draperies.  Children 
and adults should be alerted to the hazards of high surface temperature and should stay away to avoid burns or clothing 
ignition. Young children should be carefully supervised when they are in the same room as the Mendota Gas Fireplace. 

Clothing or other flammable material should not be placed on or near the Fireplace. 

Any safety screen or guard removed for servicing an appliance must be replaced prior to operating this appliance. 

The  Mendota  Gas  Fireplace is a powerful and efficient heating unit.  It has been designed as a major source of supple-
mental heat. As with any mechanical appliance there can be component shut downs.  It is advisable to have an alternate 
heat supply. 

Installation,  repair  and  any  adjustments  to  logs  or  burner  must  be  done  by  a  qualified  service  person.    The  appliance 
should  be  inspected  before  use  and  at least  annually  by  a  professional  service  person.  More frequent cleaning may be 
required due to excessive lint from carpeting, bedding material, carbon build-up, etc.  It is imperative that control compart-
ments,  burners  and  circulating  air  passageways  of  the  appliance  be  kept  clean.    The  burner  and  pilot  flames  and  logs 
should be visually checked periodically. 

DO NOT use this appliance if any part has been under water or exposed to moisture corrosion.  Immediately call a quali-
fied service technician to inspect the Fireplace and replace any part of the control system and any gas control, which has 
been under water.  DO NOT use this fireplace if the burner does not light immediately.  Turn unit off and call Mendota ap-
proved service person if there is any delay in burner light off. 

It is Johnson Gas Appliance Company's policy that no responsibility is assumed by the Company or by any of its employ-
ees or representatives for any damages caused by an inoperable, inadequate, or unsafe condition which is the result, ei-
ther directly or indirectly, of any improper operation, installation or servicing procedures. 

Building Permit and Installation Inspection Approval Requirements 

All installations of Mendota Fireplaces and Inserts must comply with all the requirements stated in this Installation and Op-
erating Instructions Manual.  The Dealer and/or installer must also obtain all required Building Permits and Inspection Ap-
proval  from  the  local  building  inspection  department  or  the  local  body  having  jurisdiction.    In  order  to  validate  warranty 
coverage, Mendota may require facsimile copies of the Building Permit and Inspection Approval forms.  Failure to provide 
adequate proof that the installation conforms to all local requirements and the requirements stated in the Installation and 
Operating Instructions Manual will void all applicable warranty. 

 

INSTALLER:  THESE INSTRUCTIONS ARE TO REMAIN WITH HOMEOWNER. 

HIGH ALTITUDE INSTALLATION INFORMATION

: Prior to installing at altitudes higher than 7500, please con-

tact the Mendota technical service department for specific venting requirements and venting restrictions. 

 

Summary of Contents for FV41-PF2

Page 1: ...rvice must be performed by a qualified installer service agency or the gas suppli er WARNING Do NOT use this appliance if any part has been under water Immediately call a qualified service technician...

Page 2: ...ilis uniquement avec les types de gas indiqu s sur la plaque signal tique Ne pas l utiliser avec d autres gas sauf si un kitde conversion certifi est install READ and UNDERSTAND all instructions caref...

Page 3: ...stem is disassembled for any reason reinstall per the instructions provided for the initial installation The vent system assembly for this fireplace must be periodically examined by a qualified servic...

Page 4: ...FIRST TIME PILOT LIGHTING INSTRUCTIONS 11 INITIALIZING THE REMOTE CONTROL SYSTEM 11 Synchronizing Receiver and Transmitter 11 IPI STANDING PILOT SYSTEM INFORMATION 12 CPI Standing Pilot Mode If set to...

Page 5: ...NOT BE PLACED on or near the appliance Children and adults should be ALERTED to the hazards of high surface temperature and should STAY AWAY to avoid burns or clothing ignition Young children should...

Page 6: ...UNIT BOTTOM TO ENCLOSURE CEILING 50in 127 cm VENT PIPE BOTTOM TO COMBUSTIBLES 1in 25mm UNIT BOTTOM TO ROOM CEILING 72 in 1829 mm 8 MANTLE ABOVE DISCHARGE AIR OPENING 18 in 457 mm MINIMUM COMBUSTIBLE...

Page 7: ...t annually by a professional service person More frequent cleaning may be required due to excessive lint from carpeting bedding material carbon build up etc It is imperative that control compart ments...

Page 8: ...until the room temperature in creases 1 o F above the Set Point Temperature To increase the Set Point Temperature Press the UP button until the desired temperature is displayed in the SET POINT TEMPE...

Page 9: ...so extinguish If in Standing Pilot Mode the pilot light will remain ON Note If in SMART model the flame height function is not available for manual adjustment In SMART mode the flame height regulates...

Page 10: ...ries used the number of ignitions of the appliance the number of changes to the room thermostat set point etc When the Transmitter bat teries are low a Battery Icon will appear on the LCD display of t...

Page 11: ...the pilot is burning steadily 7 Once the pilot flame is lit and well established close glass door WARNING NEVER IGNITE MAIN BURNERS WITH GLASS DOOR REMOVED OR OPEN Doing so will lead to damage to pilo...

Page 12: ...n the CPI Standing Pilot mode to allow the pilot light to remain on indefinitely by setting the Remote Transmitter to CPI mode If the remote transmitter is set to the IPI Intermittent Pilot mode the p...

Page 13: ...O REPLACE DOOR 1 With the Glass Door at a sharp angle to the firebox line up the three bottom tabs in glass frame bottom with slots in glass clips on firebox bottom Insert tabs into slots and center t...

Page 14: ...P a g e FV 41 LOG SET INSTALLATION INSTRUCTIONS FOLLOW EACH STEP DEPICTED IN THE DIAGRAMS BELOW TO INSTALL THE LOG SET CAUTION LOGS ARE FRAGILE HANDLE LOG PIECES WITH CARE FV 41 LOG SET PARTS IDENTIFI...

Page 15: ...85 03 00890 15 P a g e...

Page 16: ...85 03 00890 16 P a g e...

Page 17: ...85 03 00890 17 P a g e...

Page 18: ...85 03 00890 18 P a g e...

Page 19: ...85 03 00890 19 P a g e...

Page 20: ...85 03 00890 20 P a g e...

Page 21: ...85 03 00890 21 P a g e...

Page 22: ...85 03 00890 22 P a g e PLACE SMALL COALS ON TOP OF FLOOR BRICK PANELS AND CLOSE TO GRATE BOTTOM TO SIMULATE A COAL BED...

Page 23: ...ing the blower on increases the overall efficiency of this fireplace and aids in distributing and circulating heat to the room this fireplace is installed in BLOWER OPERATION The remote control system...

Page 24: ...horizontal and vent runs 1000 sealant must be used on inner joints at adjustable pipe sections CHECK FOR PROPER CLEARANCES TO COMBUSTIBLES VENT LOCATIONS Per Manual INSTALL PROPER SIZE GAS LINES CHEC...

Page 25: ...85 03 00890 25 P a g e TAPE SHUT JOHNSON GAS APPLIANCE COMPANY 520 E AVENUE N W CEDAR RAPIDS IA 52405 POSTAGE NEEDED...

Page 26: ...purchases that have not received prior written approval from Mendota NOTE Minor warping of certain parts or discoloration is normal and is not a defect covered by this warranty Major warping of parts...

Page 27: ...85 03 00890 27 P a g e Johnson Gas Appliance Company 520 E Avenue N W Cedar Rapids IA 52405 Mendota Hearth Division WEBPAGE www johnsongas com or www mendotahearth com...

Reviews: