background image

85-03-00890                        2 | P a g e  

 

In the Commonwealth of Massachusetts: 

 

Installation must be performed by a licensed 
plumber or gas fitter; 

 

A CO detector shall be installed in the room 
where the appliance is installed.

 

WARNING

:    Improper  installation,  adjustment,  altera-

tion, service or maintenance can cause injury or proper-
ty  damage.    Refer  to  this  manual.    For  assistance  or 
additional  information  consult  a  qualified  installer,  ser-
vice agency or the gas supplier. 

FOR YOUR SAFETY 

A qualified installer, service agency, or the gas suppli-

er must perform installation and service. 

Do not store or use gasoline or other flammable va-

pors and liquids in the vicinity of this or any other ap-
pliance. 

WARNING 

Do not operate this appliance with the glass removed, 

cracked or broken.  A licensed or qualified person 
should do replacement of glass.  

AVERTISSEMENT. Ne pas utiliser l’appareil si le 
panneau frontal en verre 

n’est pas en place, est 

craqué ou brisé. Confiez le remplacement du panneau 
à un technicien agréé. 

WARNING 

Mendota gas fireplaces are heat producing applianc-

es.  Do not burn wood, paper or other materials in this 
fireplace.  This fireplace is designed as a supplement 
heat source. It is advisable to have an alternative pri-
mary heat supply. 

 

WA 
 

 

The installation must conform with local codes or, in the 
absence  of  local  codes,  to  the  current  National  Fuel 
Gas  Code,  ANSI  Z223.1  (NFPA  54)  or  CAN/CGA 
B149.1 Installation Code. 

Installer  l'appareil  selon  les  codes  ou  règlements 
locaux, ou, en l'absence de tels règlements, selon 
les Codes d'installation CAN/CGA-B149.

 

This appliance may be installed in an aftermarket per-
manently located, manufactured (mobile) home (USA 
Only), where not prohibited by local codes. 
 
This appliance is only for use with the type(s) of gas 
indicated on the rating plate.  This appliance is not con-
vertible for use with other gases, unless a certified kit is 
used. 
 
Cet appareil peut être installé dans un maison 
préfabriquée (mobile) déjà installée à demeure si les 
règlements locaux le permettent. 
 
Cet appareil doit être utilisé uniquement avec les types 
de gas indiqués sur la plaque signalétique.  Ne pas 
l’utiliser avec d’autres gas sauf si un kitde conversion 
certifié est installé.

 

 

 
READ and UNDERSTAND

 all instructions carefully before starting the appliance. 

FAILURE TO

 

FOLLOW

 these instruc-

tions may result in a possible fire hazard and will void the warranty. 

Any safety screen or guard removed for servicing must be replaced before operating this appliance.

 Tout écran ou protecteur 

retiré pour permettre l’entretien de l’appareil doit être remis en place avant de mettre l’appareil en marche.

 

 

READ and UNDERSTAND

 all instructions carefully before starting the appliance. 

FAILURE TO

 

FOLLOW

 these instruc-

tions may result in a possible fire hazard and will void the warranty. 

 

Any safety screen or guard removed for servicing must be replaced before operating this appliance.

 Tout écran ou protecteur 

retiré pour permettre l’entretien de l’appareil doit être remis en place avant de mettre l’appareil en marche.

 

 

THIS UNIT IS NOT FOR USE WITH SOLID FUEL. 

 

Installation and repair should be 

PERFORMED

 by a qualified service person. The appliance and venting system should be 

INSPECTED

 before initial use and at least annually by a professional service person. More frequent cleaning may be re-

quired due to excessive lint from carpeting, bedding, material, etc. It is 

IMPERATIVE

 

that the unit’s control compartment, 

burners, and circulating air passageways 

ARE KEPT CLEAN

 to provide for adequate combustion and ventilation air. 

 

Always KEEP the appliance clear and free from combustible materials, gasoline, and other flammable vapors and 
liquids. 
 
NEVER  OBSTRUCT

  the  flow  of  combustion  and  ventilation  air.  Keep  the  front  of  the  appliance 

CLEAR

  of  all  obstacles 

and materials for servicing and proper operation. 

 

Due to high temperature, the appliance should be 

LOCATED

 out of traffic areas and away from furniture and draperies. 

En raison des températures élevées, l’appareil devrait être installé dans un endroit où il y a peu de circulation et loin du 
mobilier et des tentures. 

 

Clothing  or  flammable  material 

SHOULD  NOT  BE  PLACED

  on  or  near  the  appliance.  On  ne  devrait  pas  placer  de 

vêtements ni d’autres matières inflammables sur l’appareil ni à proximité. 

Summary of Contents for FV41-PF2

Page 1: ...rvice must be performed by a qualified installer service agency or the gas suppli er WARNING Do NOT use this appliance if any part has been under water Immediately call a qualified service technician...

Page 2: ...ilis uniquement avec les types de gas indiqu s sur la plaque signal tique Ne pas l utiliser avec d autres gas sauf si un kitde conversion certifi est install READ and UNDERSTAND all instructions caref...

Page 3: ...stem is disassembled for any reason reinstall per the instructions provided for the initial installation The vent system assembly for this fireplace must be periodically examined by a qualified servic...

Page 4: ...FIRST TIME PILOT LIGHTING INSTRUCTIONS 11 INITIALIZING THE REMOTE CONTROL SYSTEM 11 Synchronizing Receiver and Transmitter 11 IPI STANDING PILOT SYSTEM INFORMATION 12 CPI Standing Pilot Mode If set to...

Page 5: ...NOT BE PLACED on or near the appliance Children and adults should be ALERTED to the hazards of high surface temperature and should STAY AWAY to avoid burns or clothing ignition Young children should...

Page 6: ...UNIT BOTTOM TO ENCLOSURE CEILING 50in 127 cm VENT PIPE BOTTOM TO COMBUSTIBLES 1in 25mm UNIT BOTTOM TO ROOM CEILING 72 in 1829 mm 8 MANTLE ABOVE DISCHARGE AIR OPENING 18 in 457 mm MINIMUM COMBUSTIBLE...

Page 7: ...t annually by a professional service person More frequent cleaning may be required due to excessive lint from carpeting bedding material carbon build up etc It is imperative that control compart ments...

Page 8: ...until the room temperature in creases 1 o F above the Set Point Temperature To increase the Set Point Temperature Press the UP button until the desired temperature is displayed in the SET POINT TEMPE...

Page 9: ...so extinguish If in Standing Pilot Mode the pilot light will remain ON Note If in SMART model the flame height function is not available for manual adjustment In SMART mode the flame height regulates...

Page 10: ...ries used the number of ignitions of the appliance the number of changes to the room thermostat set point etc When the Transmitter bat teries are low a Battery Icon will appear on the LCD display of t...

Page 11: ...the pilot is burning steadily 7 Once the pilot flame is lit and well established close glass door WARNING NEVER IGNITE MAIN BURNERS WITH GLASS DOOR REMOVED OR OPEN Doing so will lead to damage to pilo...

Page 12: ...n the CPI Standing Pilot mode to allow the pilot light to remain on indefinitely by setting the Remote Transmitter to CPI mode If the remote transmitter is set to the IPI Intermittent Pilot mode the p...

Page 13: ...O REPLACE DOOR 1 With the Glass Door at a sharp angle to the firebox line up the three bottom tabs in glass frame bottom with slots in glass clips on firebox bottom Insert tabs into slots and center t...

Page 14: ...P a g e FV 41 LOG SET INSTALLATION INSTRUCTIONS FOLLOW EACH STEP DEPICTED IN THE DIAGRAMS BELOW TO INSTALL THE LOG SET CAUTION LOGS ARE FRAGILE HANDLE LOG PIECES WITH CARE FV 41 LOG SET PARTS IDENTIFI...

Page 15: ...85 03 00890 15 P a g e...

Page 16: ...85 03 00890 16 P a g e...

Page 17: ...85 03 00890 17 P a g e...

Page 18: ...85 03 00890 18 P a g e...

Page 19: ...85 03 00890 19 P a g e...

Page 20: ...85 03 00890 20 P a g e...

Page 21: ...85 03 00890 21 P a g e...

Page 22: ...85 03 00890 22 P a g e PLACE SMALL COALS ON TOP OF FLOOR BRICK PANELS AND CLOSE TO GRATE BOTTOM TO SIMULATE A COAL BED...

Page 23: ...ing the blower on increases the overall efficiency of this fireplace and aids in distributing and circulating heat to the room this fireplace is installed in BLOWER OPERATION The remote control system...

Page 24: ...horizontal and vent runs 1000 sealant must be used on inner joints at adjustable pipe sections CHECK FOR PROPER CLEARANCES TO COMBUSTIBLES VENT LOCATIONS Per Manual INSTALL PROPER SIZE GAS LINES CHEC...

Page 25: ...85 03 00890 25 P a g e TAPE SHUT JOHNSON GAS APPLIANCE COMPANY 520 E AVENUE N W CEDAR RAPIDS IA 52405 POSTAGE NEEDED...

Page 26: ...purchases that have not received prior written approval from Mendota NOTE Minor warping of certain parts or discoloration is normal and is not a defect covered by this warranty Major warping of parts...

Page 27: ...85 03 00890 27 P a g e Johnson Gas Appliance Company 520 E Avenue N W Cedar Rapids IA 52405 Mendota Hearth Division WEBPAGE www johnsongas com or www mendotahearth com...

Reviews: