FV33i FEATURES - QUICK REFERENCE INFORMATION
EXTERNAL DIMENSIONS
: 30-3/8” Wide X 18-3/8” High X 15-3/4” Deep (depending on Surround return depth)
GLASS SIZE
: NeoCeram Glass with non-reflective coating. Visible Glass measures 398 in
2
. Actual Glass size is
468 in
2
.
MINIMUM FIREPLACE DIMENSIONS REQUIREMENT
: 30-1/2 Wide X 18-3/8” High X 15-3/4” Deep
MANTEL ALLOWANCE
: 8” Deep Mantel at 12” Above Top Convection Opening Or 30-1/16” Above Floor Level
Of This Appliance. Use the Approved Mantel Profile Chart.
VENT SYSTEM ALLOWANCE
: Vertical Terminations Only. 10 feet Vertical Minimum. 70 feet Vertical Maximum.
4” exhaust and 3” combustion air intake pipe adapter included with unit. Only the 4” vent pipe is required to be
run the full length up to the chimney top adapter. The air intake 3” pipe may be “short-stubbed” above the existing
chimney damper. Make certain to pack insulation in the existing damper area to block outside air from flowing
through the damper.
VENT DAMPER ADJUSTMENTS AVAILABLE
: There are two vent system (air intake only) dampers installed in
this appliance:
•
PRIMARY AIR INTAKE VELOCITY ADJUSTMENT DAMPER
: This is located on the top of the Air Intake
Starter collar. This is the Primary Air Intake Velocity Adjustment damper and adjustment of this damper
must be made using a leverage tool such as a long screw driver. Factory adjusted to 45 degree Open,
this is to be adjusted towards the closed position incrementally once the length of vent system increases
past 20 feet only. Below 20 feet, leave at factory adjusted position. See page 52 for details.
•
SECONDARY AIR INTAKE ADJUSTMENT DAMPER:
This is located above the glass frame in the top
convection air cavity. Adjustment is to be made by loosening the securing nut then sliding to the right to
close and to the left to open. This is Factory adjusted to Full Closed (all the way to the right). Leave this at
this position for all installations. Adjust only in cases where more combustion air is needed to reduce rear
flame height if rear flames are engulfing the baffle brick. See page 52 for details.
CONTROLS
: IPI Electronic Ignition System with AC Primary Power and DC Backup Power. Remote Control with
Smart Thermostat included. Accent Light and Blowers operate on AC Power only.
BLOWER SYSTEM
: 210 CFM Dual Blower System. 120VAC, 2Amps. Dedicated Hot Power only. No switches,
Fan Speed Controls or Light Dimmers are allowed in same circuit.
Accent Light System
: Accent Light System Included. Light can be turned on or off and dimmed from remote con-
trol.
BURNER SYSTEM
: Dual 304 Stainless Steel Tubular burners.
BURNER SHUTTER SYSTEM
: Externally controllable Rear Burner air shutter. Internal rotary Front Burner air
shutter.
LOG SET
: 9-piece, Premium Definition Log Set. Extreme glow and realism ember bed.
REFRACTORY PANELS
: High Detail Red Soldier Course Fiber Brick Panels included. Brick Panels required for
operation.
NATURAL GAS INFORMATION
: Factory equipped for Natural Gas. 4.5”WC Minimum inlet pressure required.
For NG applications, Front Burner Orifice Size is #49 and the Rear Burner Orifice Size is #45.
LPG INFORMATION
: LP conversion kit #HA-82-00411 is required. 11”WC Minimum inlet pressure required. For
the FV33i LPG application, both front are rear burner orifices are to be drill size 3/64”. For higher altitude, adjust-
ment to orifice size may be necessary.