85-03-00955
P a g e
|
44
BEFORE YOU BEGIN
Read this entire manual before you use your new fireplace (especially the section “Safety Precautions” on page 2). Failure
to follow the instructions may result in property damage, bodily injury, or even death.
REMOTE CONTROL TRANSMITTER FUNCTIONS
NOTE
: The Wall Receiver will “beep” once every time a Remote
Transmitter Key is pressed, signaling that the command has
been received.
Identify the four function buttons on the Remote Transmitter:
On/Off Key
: This button turns the system ON or
OFF. When this button is pressed and the system
is OFF, the pilot light will stay ON if the “Standing
Pilot Switch” is in the ON position.
Thermostat Key
: This button, when pressed after
the ON/OFF KEY is pressed and the system is ON, will al-
low the selection of three modes: Manual Operation, Nor-
mal Thermostat and Smart Thermostat.
Manual Mode
: In this mode, the room temperature is ig-
nored and the fireplace can be turned ON indefinitely. The room
temperature rise has no effect on this mode. All other functions
such as fan speed control, flame height control, secondary
burner On/OFF control and Accent Light ON/OFF controls will be
manually controllable.
Normal Thermostat
: In this mode, the fireplace will stay func-
tioning until the room temperature increases 1
o
F above the Set
Point Temperature. To increase the Set Point Temperature,
Press the UP button until the desired temperature is displayed in
the SET POINT TEMPERATURE window. The fan will turn on 5
minutes after fireplace startup and will turn off 12-1/2 minutes af-
ter the flames turn off, in this mode. The flame height can be ad-
justed while the fireplace is functioning, fan speed can be
adjusted after 5 minutes of startup. Secondary burner can be
turned On or Off at any time after startup. The Accent Light can
be turned on or off any time after startup.
Smart Thermostat
: In this mode, all other functions except the
flame height adjustment are allowed. Manual flame height adjustment is not allowed in this mode. The Smart Thermostat
function adjusts the flame height in accordance to the difference between the set point temperature and the actual room
temperature. As the room temperature gets closer to the set point temperature, the Smart Function automatically modulates
the flame down.
Up/Down Key:
This key is used to increase or decrease the Set Point Temperatures, Flame Height and Fan Speed and
to toggle between Accent Light ON/OFF and Secondary Burner ON/OFF
.
Mode Selection Key:
This key is used to toggle between the various function icons : Flame Height, Fan
Speed, Accent Light and Secondary Burner.
SMART
ON
OFF
SMART
MODE
NORMAL
THERMOSTAT
MANUAL
MODE
68
Hi
MAX
MAX
Hi
OFF
76°
F
F
76°
ON
SMART
76°
F