46
You must remove the left side Valve Access Panel to replace the pressure regulator.
1.
Remove the left-side access panel mounted to the left outer skin and lay down gently without disconnecting any wires of internal
components. WARNING: DO NOT FORCE. EXCESSIVE FORCE MAY DAMAGE INTERNAL WIRING COMPONENTS!
2. See diagrams on this page and identify the Pressure Regulator on
the Valve Body.
3. Using a Torx T20 (supplied) or a slotted screwdriver, remove 2
screws that secure the NG Pressure Regulator to the gas valve
body and remove NG Pressure Regulator, see following page for
detailed instructions. Note: Be careful when removing or tighten-
ing the screw on the back-side of the pressure regulator. The
screw location is difficult to access and care must be taken to en-
sure a proper seal when tightened.
4. Install the new LP Pressure Regular onto the gas valve body in the
same position and orientation as the NG Pressure Regulator you
removed in Step 2, above. The LP Pressure Regulator can only
be mounted in one position. Secure the LP Pressure Regulator in
place. Tighten down.
5. Install pilot orifice thimble ##977.168 see Figures on page 39 for
location. To remove Pilot Hood, use a screw driver to pry open
the Wire Clip that is located at the base of the Pilot Hood. Pull
Upward and remove pilot hood. Use an Alan wrench to remove
NG Pilot Orifice. (Pilot orifice thimble is located inside pilot hood
base).
8. Install LP Pilot Orifice. Tighten down using an Alan wrench. Replace Wire Clip in its original position.
9. Push Pilot Hood down into base until it snaps in place.
RE
M
O
VE
(
4)
S
CREWS
"ONLY"
THA
T HO
LD
LE
FT S
IDE
C
OVER.
PRESSURE
REGULATOR
PRESSURE
REGULATOR
SCREWS
WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically ap-
proved with this appliance may result in property damag
e or personal injury.” AVERTISSEMENT. Risque de dommages
ou de blessures si les pièces ne sont pas installées conformément à ces schémas et ou si des pièces autres que celles
spécifiquement approuvées avec cet appareil sont utilisées.