17
14.
Remove the Vent Adapter by removing
two 5/16” Hex Bolts and sliding Vent
Adapter towards rear of Insert.
15.
Tightly secure 3” and 4” flex vents with
clamps provided. Seal vent
cap/flashing to top of chimney with
weatherproof sealer. Seal areas be-
tween flex pipes and existing chimney,
at damper area, with unfaced fiberglass
insulation.
16.
Carefully slide Insert into the fireplace
opening (Note: Plug in the AC Power
cord to a 110 volt AC receptacle inside
the fireplace opening or extend it out
and connect to a grounded wall outlet.
17.
Slide Vent Adapter forward between
guide rails. Vent Adapter’s front flat
section should contact insert top as you
slide the Vent Adapter forward.
18.
Use Glass Latch Tool to grab Vent
Adapter through slot and hole provided.
As you apply downward pressure, pull
Vent Adapter forward until front flange
on Vent Adapter is about ½” away from front lip on Insert.
19.
Slide 5/16” Hex Bolts through holes in face of Insert and start one Bolt in each of the two press nuts on
Vent Adapter Flange. Using a 5/16” Hex Hand Driver, tighten the hex bolts a few turns at a time alternat-
ing between the two hex bolts until the screws are hand tight and vent adapter is pulled fully forward.
2-7/8" AIR INTAKE
STUB
3-7/8" EXHAUST
STUB
VENT CONNECTION
ADAPTER
HEX HEAD BOLTS
10-24X1-1/4"
f i r e - p a r t s . c o m