E-FV33i FEATURES - QUICK REFERENCE INFORMATION
EXTERNAL DIMENSIONS
: 30-
3/8” Wide X 18-3/8” High X 15-3/4” Deep
GLASS SIZE
: NeoCeram Glass with non-reflective coating. Visible Glass measures 398 in
2
. Actual Glass size is 468 in
2
.
MINIMUM FIREPLACE DIMENSIONS REQUIREMENT
: 30-1/2 Wide X 18-
3/8” High X 15-3/4” Deep
MANTEL ALLOWANCE
: 8” Deep Mantel at 12” Above Top Convection Opening Or 30-1/16” Above Floor Level Of This
Appliance. Use the Approved Mantel Profile Chart.
VENT SYSTEM ALLOWANCE
: Vertical Terminations Only. 10 feet Vertical Minimum. 70
feet Vertical Maximum. 4” ex-
haust and 3” combustion air intake pipe adapter included with unit. Only the 4” vent pipe is required to be run the full
length up to the chimney top adapter.
The air intake 3” pipe may be “short-stubbed” above the existing chimney damper.
Make certain to pack insulation in the existing damper area to block outside air from flowing through the damper.
VENT DAMPER ADJUSTMENTS AVAILABLE
: There are two vent system (air intake only) dampers installed in this ap-
pliance:
PRIMARY AIR INTAKE VELOCITY ADJUSTMENT DAMPER
: This is located on the top of the Air Intake Starter
collar. This is the Primary Air Intake Velocity Adjustment damper and adjustment of this damper must be made
using a leverage tool such as a long screw driver. Factory adjusted to 45 degree Open, this is to be adjusted to-
wards the closed position incrementally once the length of vent system increases past 20 feet only. Below 20 feet,
leave at factory adjusted position. See page 52 for details.
SECONDARY AIR INTAKE ADJUSTMENT DAMPER:
This is located above the glass frame in the top convec-
tion air cavity. Adjustment is to be made by loosening the securing nut then sliding to the right to close and to the
left to open. This is Factory adjusted to Full Closed (all the way to the right). Leave this at this position for all in-
stallations. Adjust only in cases where more combustion air is needed to reduce rear flame height if rear flames
are engulfing the baffle brick. See page 52 for details.
CONTROLS
: IPI Electronic Ignition System with AC Primary Power and DC Backup Power. Remote Control with Smart
Thermostat included.
BURNER SYSTEM
: Dual 304 Stainless Steel Tubular burners.
BURNER SHUTTER SYSTEM
: Externally controllable Rear Burner air shutter. Internal rotary Front Burner air shutter.
LOG SET
: 9-piece, Premium Definition Log Set. Extreme glow and realism ember bed.
REFRACTORY PANELS
: High Detail Red Soldier Course Fiber Brick Panels and Black Porcelain panels are available.
One Panel kit must be purchased and is required for operation.
NATURAL GAS INFORMATION
: Factory equipped for Natural Gas. 4.5”WC Minimum inlet pressure required. For NG
applications, Front Burner Orifice Size is #49 and the Rear Burner Orifice Size is #45.
LPG INFORMATION
: LP conversion kit #HA-82-
00411 is required. 11”WC Minimum inlet pressure required. For the E-
FV33i LPG application, both front are rear burner orifices are to be drill siz
e 3/64”. For higher altitude, adjustment to orifice
size may be necessary.
INITIAL STARTUP ADVICE
PAINT CURING CYCLE RECOMMENDATION
: It is recommended that you run this Insert on maximum flame height for
3 cycles of 2 hours ON and 2 hours OFF initially to cure the paint.
In the Commonwealth of Massachusetts:
Installation must be performed by a licensed plumber or
gas fitter;
A CO detector shall be installed in the room where the
appliance is installed.
WARNING
If the information in this manual is not followed exactly, a
fire or explosion may result causing property damage,
personal injury or loss of life.