85-03-01115
DXV35 TIMBERFIRE
Page
67
4.7
LIGHTING CHECKLIST
Be sure to check these items before final operation of the Fireplace.
☐
All items on "Installation Checklist" must be completed.
☐
Carefully follow all lighting and log installation instructions. Make certain that pilot flame lights immediately and lights both
front and rear burners.
☐
Check for Gas leaks and gas pressures prior to installing facing materials.
☐
Air shutter opening 0
" to ⅛" natural gas or ¼” to ½” LP gas is checked.
☐
All lighting and log installation instructions were followed.
☐
Burners light immediately and flame runs promptly around rear burner and lights entire burner.
Note:
Do not proceed with operation unless burner cycles "on/off" without delays.
☐
Flame is "stable" and does not "lift" off burner. If flame lifts off burner, turn unit off and check that all vent pipes are
"twist locked" and leak proof, the vent cap is "right side up
”
. Do not proceed with operation if flame is "lifting off"
burner.
☐
DO NOT proceed with operation unless burner cycles "on/off" without delays and the flame is "stable" and not "lifting" off
burner after 5 minutes of initial ignition.
Caution: If pilot goes out, be sure to wait a minimum of five minutes before relighting.