Rough Framing Dimensions
The rough framing dimensions given are the
minimum allowed framing dimensions. Be sure
when planning the framing of the unit that
adequate paths to route the gas and electrical are
available on both sides of the unit.
SPECIAL FRAMING NOTE
:
If the fireplace is to be recessed in a cavity deeper
than 15-
1/8”, all framing and finishing materials
protruding past the front face of this fireplace
must be of the NON-COMBUSTIBLE variety.
Minimum Required Rough Framing Dimensions
DESCRIPTION
DIMENSION
(INCHES)
A
WIDTH
36-1/4
”
B
HEIGHT
31-
7/16”
C
DEPTH
15-
1/8”
E
FINISH MATERIAL THICKNESS
Varies
F
UNIT BASE TO ENCLOSURE
CEILING
53-
5/8”
G
GLASS FRAME EDGE TO SIDE
WALL
12
”
H
UNIT BASE TO 8” MANTEL
41”
MINIMUM FRAMING DIMENSIONS
WIDTH = 36-1/4
” HEIGHT = 31
-7-
16” DEPTH = 15
-
1/8”
Figure 3-17
Figure 3-18
If the mantel is constructed of non combustible materials, it may be placed at any distance above the top air gap.
Caution: Materials made of porous stones or sedimentary rocks may crack due to expansion of the material if placed around this
appliance. Use suitable materials which are crack resistant and high temperature resistant.
Summary of Contents for DXV-60
Page 14: ...85 03 01115 DXV35 TIMBERFIRE Page 14 Figure 3 10 Figure 3 9...
Page 36: ...85 03 01115 DXV35 TIMBERFIRE Page 36 Approved Vent Systems Figure 3 29 Approved Vent Systems...
Page 62: ...85 03 01115 DXV35 TIMBERFIRE Page 62...
Page 63: ...85 03 01115 DXV35 TIMBERFIRE Page 63...
Page 64: ...85 03 01115 DXV35 TIMBERFIRE Page 64...
Page 85: ......