DXV35 TIMBERFIRE
Page
18
Fireplace Dimensions and Clearances
MINIMUM FRAMING DIMENSIONS
WIDTH = 36-1/4
” HEIGHT = 31
-7-
16” DEPTH = 15
-
1/8”
Figure 3-13
Figure 3-14
Figure 3-15
Figure 3-16
A wall, perpendicular and in front of this appliance's glass door face must be at least 12" away from the side edges of
the glass frame (Figure 3-13).
A wall at a 45
angle to the front face and starting at the Side Edge of the Front Face of this appliance is allowed.
Projections behind this 45
angle edge (shaded area) are allowed.
Caution: The distance from floor level to the centerline of the vent cap is based on Simpson DuraVent GS components.
If using vent components of another brand, do not assume that the measurement given here is applicable. Verify the
distance to the centerline of vent cap by measuring the components you are using.
Note:
For every 1” this fireplace is raised off the floor, the non
-combustible hearth protection pad may be reduced by
2”. If this fireplace is raised more than 6” off the floor, no hearth protection pad is required. See
Chapter 3.2.4.2 Hearth
Pad Requirement
and
Chapter 3.2.5.1 Hearth Pad Temperatures
.