85-03-01115
DXV35 TIMBERFIRE
Page
61
4.5
TIMBERFIRE LOG SET INSTALLATION
With door removed, proceed as follows:
1.
Before placing log assembly in firebox, fill space under Log Grate with coals.
2.
Follow the diagrams below in the sequence given. Start by identifying the Log Pins and Pin Hole in the Airbox. Next, identify
the log pieces according to the diagram below.
3.
Place glowing embers (wool) sparsely on top coals, in front of front log. Additional wool may be rubbed on front surfaces of
log for additional glow. Add wool to "burned out" space between front logs. Fill area to back burner.
WARNING: Do not block holes with excessive wool. Delayed ignition and sooting can occur
.
4.
With glass removed, light pilot, and check for smooth ignition. Reinstall door, and check for smooth ignition. If any delay occurs,
make sure that no coals or wool is blocking pilot from front or rear burner holes.
5.
Reinstall door, and check for smooth ignition again. If any delay occurs, make sure that no coals or wool is blocking pilot from
front or rear burner holes. Remove glass door, correct problem and repeat steps 4 and 5.