2

Height

Width

Depth

Depth with Lip plate

Weight

Loxton 3

525

380

280

60 kg

Loxton 5

606

490

320

380

71 kg

Loxton 6

606

490

340

400

81 kg

Loxton 8

660

490

400

460

91 kg

Loxton 10

660

705

400

460

110kg

Loxton 6 pedestal

960

490

340

400

91 kg

Loxton 8 pedestal

1040

490

400

460

105 kg

Loxton 10 pedestal

1040

705

400

460

125 kg

Churchill 5

606

490

380

71 kg

Churchill 6

606

490

400

81 kg

Churchill 8

660

490

460

91 kg

Chuchill 10

660

705

460

110 kg

Churchill 6  pedestal

960

490

400

91 kg

Churchill 8  pedestal

1040

490

460

105 kg

Churchill 10 pedestal

1040

705

460

125kg

Churchill 6  convection

606

575

400

88 kg

Churchill 8  convection

660

575

460

110g

Churchill 10 convection

660

790

460

118 kg

Churchill 6  pedestal convection

960

575

400

103kg

Churchill 8  pedestal convection

1040

575

460

117kg

Churchill 10  pedestal convection

1040

790

460

133kg

Sqabox unO

606

490

320

71 kg

Sqabox duO

606

490

340

81 kg

Installation Manual and Operating instructions

LOXTON 3kW
LOXTON 5 kW,  LOXTON 6 kW,  LOXTON 6  PEDESTAL
LOXTON 8 kW   LOXTON 8  PEDESTAL
LOXTON 10kW  LOXTON 10 PEDESTAL

CHURCHILL 5 kW, CHURCHILL 6 kW,  CHURCHILL 6 PEDESTAL
CHURCHILL 8 kW   CHURCHILL 8 PEDESTAL
CHURCHILL 10 kW  CHURCHILL 10 PEDESTAL
CHURCHILL 6 kW  convection,    CHURCHILL 6 PEDESTAL convection
CHURCHILL 8 kW  convection,    CHURCHILL 8 PEDESTAL convection
CHURCHILL 10 kW convection,   CHURCHILL 10 PEDESTAL convection

SQABOX

TM

 unO

SQABOX

TM

  duO

This manual refers to the stoves listed above, which are tested in accordance with EN 13240.

Congratulations on your purchase of a new stove from Mendip Stoves. Please read this manual carefully to ensure that you

get maximum enjoyment from your new stove and to prevent any problems. Please note that “all local regulations, including
those referring to national and European Standards, need to be complied with when installing this appliance”.

For  further  information  on  installing  and  using  fireplaces  and  wood  burning  stoves,  please  see  the  relevant  building
regulations that apply to the country in which Loxton ,Churchill and Sqabox   have been approved, as well as the relevant
brochure on the correct use of wood burning stoves available from your local stove supplier or your Chimney sweep.

These instructions cover the basic principals to ensure the satisfactory installation for Loxton/Churchill/Sqabox multi-fuel

stove, although detail may need slight modification to suit particular local site conditions.

Summary of Contents for Loxton 8

Page 1: ...1 OPERATION AND INSTALLATION MANUAL Multi fuel and SE models Loxton 3 5 6 8 10 Churchill 5 6 8 10 Sqabox unO duO...

Page 2: ...URCHILL 6 PEDESTAL CHURCHILL 8 kW CHURCHILL 8 PEDESTAL CHURCHILL 10 kW CHURCHILL 10 PEDESTAL CHURCHILL 6 kW convection CHURCHILL 6 PEDESTAL convection CHURCHILL 8 kW convection CHURCHILL 8 PEDESTAL co...

Page 3: ...CHECKS IMPORTANT WARNING This stove must not be installed into a chimney that serves any other heating appliance There must not be an extractor fan fitted in the same room as the stove because this c...

Page 4: ...C 12 pa Loxton 8 5 8 7 1 g sec 291 332deg C 12 pa Loxton 10 6 9g sec 325deg C 12 pa Churchill 5 4 3 4 7 g sec 231 221deg C 12 pa Churchill 6 4 3 4 7 g sec 231 221deg C 12 pa Churchill 8 5 8 7 1 g sec...

Page 5: ...fitted in place of an open fire then the chimney should be swept one month after installation to clear any soot falls which may have occurred due to the difference in combustion between the stove and...

Page 6: ...ush Only Use a damp cloth on external surfaces Over time the glass may become dirty clean with a damp cloth and polish off with damp cloth If the stove has not been used for some time the flue should...

Page 7: ...construction so that it is in accordance with the provisions of the current Building Regulations Approved Document J The clearance distances to combustible material beneath surrounding or on the hear...

Page 8: ...te This collar allows connection to either a masonry chimney or a prefabricated factory made insulated metal chimney Commissioning and handover Ensure loose parts are fitted in accordance with the ins...

Page 9: ...couple of firings therefore preventing the door seal cord around the door from sticking and coming away from the door Once the heat resistant paint has hardened the smell will disappear This stove is...

Page 10: ...for smoke control areas see page 4 alterations should not be attempted Mendip smoke control stoves should not be burnt with the door left open The refuelling procedure allow the newly charged fuel to...

Page 11: ...ood Newly cut wood should be stacked and air dried under cover for two years before being used as firewood Do not burn liquid fuels drift wood finished sawn wood pallet wood chipboard plywood varnishe...

Page 12: ...r hand from possible heat The handle has push pull motion as shown above When shutting the door push the door closed and push handle firmly until the door latches PARTS Always use the operating tools...

Page 13: ...m paint lacquer spray available from your Mendip dealer To clean the outside of the stove use a dry cloth Sweeping your chimney Ensure that your appliance flue ways and chimney are swept regularly Thi...

Page 14: ...fails to heat fully a The firewood may be too wet b the intake of secondary air may be insufficient 5 Smoke or odour a Weak chimney draft b check for blockages in the flue pipe chimney c check the he...

Page 15: ...ess fuels only HETAS recommended fuels Please note that HETAS Ltd Appliance Approval only covers the use of wood logs and approved smokeless fuels on this appliance HETAS Ltd Approval does not cover t...

Page 16: ...e Ltd Unit H1 Mendip Industrial Estate Mendip Road Rooksbridge Somerset BS26 2UG Tel 01934 750 500 Fax 01173 156 207 www Mendipstoves co uk E mail info mendipstoves co uk Mendip Stoves Ltd 2013 ver 5...

Reviews: