Flue and Chimney connection to your stove (continued)
If it is found that there is excessive draught in the chimney then either an adjustable flue damper or alternately a draught
stabiliser should be fitted. The adjustable flue damper should not close off the flue entirely but should in its closed position
leave a minimum continuous opening free area of at least 20 % of the total cross sectional area of the flue or flue pipe.
Adequate provision e.g. easily accessible soot door or doors must be provided for sweeping the chimney and connecting flue
pipe
Your appliance needs to be maintained routinely, the throat plate/baffle should be cleaned regularly (monthly) . The flue
pipe can be cleaned using a flexible brush. Only Use a damp cloth on external surfaces. Over time the glass may become
dirty, clean with a damp cloth and polish off with damp cloth. If the stove has not been used for some time the flue should
be checked for blockages before use.
Do not modify the appliance; only use spares authorised by the manufacturer.
B
C
E
A
D
F
A
B
C
D
E
F
F Ped
Loxton 3
525mm
380mm
280mm
125mm
107mm
400mm
N/A
Loxton 5
606mm
490mm
320mm
125mm
115mm
480mm
N/A
Loxton 6
606mm
490mm
340mm
125mm
115mm
480mm
825mm
Loxton 8
660mm
490mm
400mm
150mm
115mm
530mm
825mm
Loxton 10
660mm
705mm
400mm
150mm
110mm
530mm
905mm
Churchill 5
606mm
490mm
380mm
125mm
115mm
480mm
N/A
Churchill 6
606mm
490mm
400mm
125mm
115mm
480mm
825mm
Churchill 8
660mm
490mm
460mm
150mm
115mm
530mm
825mm
Churchill 10
660mm
705mm
460mm
150mm
110mm
530mm
905mm
Sqabox unO
606mm
490mm
320mm
125mm
110mm
480mm
N/A
Sqabox duO
606mm
490mm
340mm
125mm
110mm
480mm
N/A