Mendip Stoves Insulated chambers

Mendip Stoves are  lined with vermiculite heat deflection panels and baffles, these panels are designed to ensure the
maximum efficiency and are an integral part of the clean burn process of the stove. These baffles should not be removed
other than for cleaning the stove. Any defective panels should be replaced.
Place fuel into the fire fire chamber of your stove,  impact from logs can cause  the heat deflection panel to crack

.

Connection to chimney

Mendip Stoves are factory set up with a top flue outlet, this can be altered from top to  rear connection, remove the top
collar and rear cover plate and exchanging collar and plate. Care should be taken to ensure an airtight fit when refitting
collar and plate. A decorative cover plate is included with every stove to cover the hole in the convection top plate.

This collar allows connection to either a masonry chimney or a prefabricated factory made insulated metal chimney.

Commissioning and handover

Ensure loose parts are fitted in accordance with the instructions  given in the instruction booklet. On completion of the
installation allow a suitable period of time for any fire cement and mortar to dry out, a small fire may be lit to check that
smoke and fumes are taken from the stove up the chimney and emitted safely into the atmosphere. Do not run at full
output for at least 24 hours.

On completion of the installation and commissioning ensure that the operating instructions for the stove are left with

the customer. Ensure to advise the customer on the correct use of the appliance with the fuels likely to be used in the
stove and notify them to use only the recommended fuels for the stove.

Advise the user what to do should smoke or fumes be emitted from the stove. The customer should be warned to use a

fireguard to BS 8423:2002 in the presence of children, aged and/or infirm persons.

Summary of Contents for Loxton 8

Page 1: ...1 OPERATION AND INSTALLATION MANUAL Multi fuel and SE models Loxton 3 5 6 8 10 Churchill 5 6 8 10 Sqabox unO duO...

Page 2: ...URCHILL 6 PEDESTAL CHURCHILL 8 kW CHURCHILL 8 PEDESTAL CHURCHILL 10 kW CHURCHILL 10 PEDESTAL CHURCHILL 6 kW convection CHURCHILL 6 PEDESTAL convection CHURCHILL 8 kW convection CHURCHILL 8 PEDESTAL co...

Page 3: ...CHECKS IMPORTANT WARNING This stove must not be installed into a chimney that serves any other heating appliance There must not be an extractor fan fitted in the same room as the stove because this c...

Page 4: ...C 12 pa Loxton 8 5 8 7 1 g sec 291 332deg C 12 pa Loxton 10 6 9g sec 325deg C 12 pa Churchill 5 4 3 4 7 g sec 231 221deg C 12 pa Churchill 6 4 3 4 7 g sec 231 221deg C 12 pa Churchill 8 5 8 7 1 g sec...

Page 5: ...fitted in place of an open fire then the chimney should be swept one month after installation to clear any soot falls which may have occurred due to the difference in combustion between the stove and...

Page 6: ...ush Only Use a damp cloth on external surfaces Over time the glass may become dirty clean with a damp cloth and polish off with damp cloth If the stove has not been used for some time the flue should...

Page 7: ...construction so that it is in accordance with the provisions of the current Building Regulations Approved Document J The clearance distances to combustible material beneath surrounding or on the hear...

Page 8: ...te This collar allows connection to either a masonry chimney or a prefabricated factory made insulated metal chimney Commissioning and handover Ensure loose parts are fitted in accordance with the ins...

Page 9: ...couple of firings therefore preventing the door seal cord around the door from sticking and coming away from the door Once the heat resistant paint has hardened the smell will disappear This stove is...

Page 10: ...for smoke control areas see page 4 alterations should not be attempted Mendip smoke control stoves should not be burnt with the door left open The refuelling procedure allow the newly charged fuel to...

Page 11: ...ood Newly cut wood should be stacked and air dried under cover for two years before being used as firewood Do not burn liquid fuels drift wood finished sawn wood pallet wood chipboard plywood varnishe...

Page 12: ...r hand from possible heat The handle has push pull motion as shown above When shutting the door push the door closed and push handle firmly until the door latches PARTS Always use the operating tools...

Page 13: ...m paint lacquer spray available from your Mendip dealer To clean the outside of the stove use a dry cloth Sweeping your chimney Ensure that your appliance flue ways and chimney are swept regularly Thi...

Page 14: ...fails to heat fully a The firewood may be too wet b the intake of secondary air may be insufficient 5 Smoke or odour a Weak chimney draft b check for blockages in the flue pipe chimney c check the he...

Page 15: ...ess fuels only HETAS recommended fuels Please note that HETAS Ltd Appliance Approval only covers the use of wood logs and approved smokeless fuels on this appliance HETAS Ltd Approval does not cover t...

Page 16: ...e Ltd Unit H1 Mendip Industrial Estate Mendip Road Rooksbridge Somerset BS26 2UG Tel 01934 750 500 Fax 01173 156 207 www Mendipstoves co uk E mail info mendipstoves co uk Mendip Stoves Ltd 2013 ver 5...

Reviews: