background image

18 of 28

CHRISTON 550 / 750 COMBUSTION CHAMBER

Secondary air
/air wash

Ter�ary Air jets

Vermiculite
brick set

Log retainer

Rear firebrick
support bracket

Primary air box

Baffle support
bar

Figure #

Part Descrip�on

Christon 550 - Part Code

Christon 750 - Part Code

1

Base Brick Pair

M10550-02-22-99-00

M10750-02-22-99-00

2

Rear Brick Pair

M10550-02-23-99-00

M10750-02-23-99-00

3

Side Brick Pair

M10550-02-24-99-00

M10750-02-24-99-00

4

Baffle Brick Pair

M10550-02-26-99-00

M10750-02-26-99-00

5

Upper Baffle Brick Pair

M10550-02-58-99-00

M10750-02-58-99-00

CHRISTON 550 / 750 BRICK SET REFERENCE KEY AND PRODUCT CODES

Summary of Contents for Christon 550

Page 1: ...1 of 28 OPERATION AND INSTALLATION MANUAL Woodburning SE models Christon 550 Christon 750 ENG December 2019...

Page 2: ...y to the country in which your stove is installed and tested These instruc ons cover the basic principals to ensure the sa sfactory installa on of your stove although detail may need slight modifica o...

Page 3: ...m manufacturer s instruc ons Provision of an alarm must not be considered a subs tute for either installing the appliance correctly or ensuring regular servicing and maintenance of the appliance and c...

Page 4: ...a on procedure given in BS5854 1980 may be used as the basis for deciding whether a par cular chimney design will provide sufficient draught If it is found that there is excessive draught in the chimn...

Page 5: ...n 550 750 have been recommended as suitable for use in smoke control areas when burning wood logs and when fi ed with a mechanical stop to prevent closure of the secondary ter ary air control Christon...

Page 6: ...MENSIONS AND CONNECTION MEASUREMENTS 745 550 10 20 154 355 80 372 5 1 2 5 1 2 5 112 5 105 10 550 550 E E 550 75 75 105 105 275 105 105 136 26 22 5 198 256 11 5 550 10 80 52 1 6 7 Christon 750 Christon...

Page 7: ...mm thick in accordance with Building Regula ons Approved Document J to a distance of 30 cm in front of the stove and 15 cm to each side measuring from the door of the combus on chamber HEARTH COMBUST...

Page 8: ...c on to either a masonry chimney or a prefabricated factory made insulated metal chimney COMBUSTION CHAMBERS INSTALLING A CHRISTON INSET N B Inset models are supplied with a stainless steel adapter wh...

Page 9: ...ernal air is directed into the combus on chamber By moving the control lever to the le increases the primary air mix moving the UAC to the right increases the secondary air Whatever posi on the contro...

Page 10: ...wood plays an important role since the use of wet wood results in poor fuel economy and may cause a tarry sooty film on the internals of the stove Newly cut wood contains 60 70 water making it totally...

Page 11: ...ponsible for implemen ng the Clean Air Act 1993 including designa on and supervision of smoke control areas and you can contact them for details of Clean Air Act requirements The Christon 550 750 SE s...

Page 12: ...bed If thereis insufficientburning materialin the firebed tolight anew fuelcharge excessivesmoke emissioncan occur Refuelling must be carried out onto a sufficient quan ty of glowing embers and ash th...

Page 13: ...Mendip stoves do not recommend that their stoves are burnt overnight for this reason As a night me regime we recommend that the fireis loadedwhen hotand burntfor fiveminutes withthe secondaryair cont...

Page 14: ...lit stove The use of any aerosol is dangerous and care must be taken handling aerosols 1 Fire Will Not Burn check a the air inlet is not obstructed in any way b that chimney and flue ways are clear c...

Page 15: ...tove linings To remove ash pan use a ash shovel always wear a heat resistant glove Make sure the stove is completely cold before cleaning out ash embers can remain hot for over 24 hours Ash must be st...

Page 16: ...visit www eurostove co uk for latest spare part informa on Always use the opera ng tools provided when handling parts likely to be hot when the stove is in use Your stove has the following parts in t...

Page 17: ...17 of 28 1 1 7 8 4R 5 3 3 6 2L 1 1 2R 4L 5L 5R CHRISTON 550 750 COMBUSTION CHAMBER SPARE PART CODES...

Page 18: ...rip on Christon 550 Part Code Christon 750 Part Code 1 Base Brick Pair M10550 02 22 99 00 M10750 02 22 99 00 2 Rear Brick Pair M10550 02 23 99 00 M10750 02 23 99 00 3 Side Brick Pair M10550 02 24 99 0...

Page 19: ...et Tilt an upper baffle brick forward and to the centre in order to remove Your flue system can now be accessed through the stove but for added protec on when sweeping it is advised that all the brick...

Page 20: ...20 of 28 Christon 550 Freestanding Inset Christon 750 Freestanding Inset CHRISTON 550 750 COMBUSTION CHAMBER CAN BE REMOVED FROM OUTER FRAME...

Page 21: ...Christon 550 Inset Christon 750 Inset Christon 750 Freestanding To purchase or get more informa on on spare parts for the Christon Models please visit www mendipstoves co uk mp spares christon catego...

Page 22: ...0 00 M10750 06 00 00 00 1 Door Handle M10750 06 05 99 00 M10750 06 05 99 00 2 Glass M10550 01 27 99 00 M10750 01 27 99 00 3 Door Rope Seal M10550 06 02 00 00 M10750 06 02 00 00 4 Glass Rope Seal M1055...

Page 23: ...feet have been removed roughly posi on the stove inline with the base Then carefully li one side of the stove and remove the wooden batons allowing the stove to come to rest upon the logstore 4 It is...

Page 24: ...ethe topplate protrusionbetween the stove body and the log base If this has been posi oned correctly the threaded holes of the top plate will be accessible through the logstore base of the Christon Th...

Page 25: ...25 of 28 EN TEST RESULTS CHRISTON 550 Essen al Characteris c Descrip on...

Page 26: ...26 of 28 EN TEST RESULTS CHRISTON 750 Essen al Characteris c Descrip on...

Page 27: ...27 of 28 39 of 40...

Page 28: ...0 750 Manual Version Mendip Stoves Ltd Unit H1 Mendip Industrial Estate Mendip Road Rooksbridge Somerset BS26 2UG Website www mendipstoves co uk Email info eurostove co uk Telephone 01934 750 500 Part...

Reviews: