20 INSTALLATION AND CONFIGURATION
3006M100-002
20-19
Procedure 8:
Installing -48V/Ring Generator Module (Standalone)
This procedure assumes that you will be installing only the -48V/Ring Generator
Module. If you are installing the -48V/Ring Generator Module and DEM,
disregard this procedure and complete Procedure 7.
This procedure assumes that you have removed the cover from the chassis
(Procedure 2).
To install the -48V/Ring Generator Module:
1.
Ground yourself to protect the I/O cards from electrostatic discharge (ESD).
2.
Remove -48V/Ring Generator Module from its packaging.
3.
Align the -48V/Ring Generator Module over the motherboard so that its 12-
pin header at P1 is over connector J2 on the motherboard.
Figure 20-16 -48V/Ring Generator Module Installation