For Build 050109 and later
7
Equipment connected to the WAN port
WILL BE
damaged
if the device does not support Power over
CAT5. Use the supplied power blocker or custom cables
to prevent trouble!
L’`equippement connecte` `a la prise WAN SERA
ENDOMMAGE` si le dispositif ne tole`re pas POWER
sur CAT5. Enployez le bloque courent fourni ou les
cables particuliers pour prevenir des probl`emes.
Lightning arrestor(s) are required for each ethernet
cable entering the facility.
Des bloque/`eclair sont requis pour chaque cable
Ethernet qui rentre dans le local.
WARNING: Each Lightning arrestor must have a separate
and permanent connection to protective earth.
ATTENTION: Chaque bloque/`éclair doit ^etre muni
dune cable de terre
separe` et permanent.
5.
Connect each local equipment DS1 port to an equipped DS1 port
on the Flanger4Plus. In most cases the DS1 cable needs to be a
cross-over. LINK will light when the port is enabled and signal is
present. ACTIVITY will flash when there is DS1 activity.
Note that a DS1 crossover cable is DIFFERENT than
an Ethernet crossover cable. Refer to the
DS1 with RJ-
45 Cable Diagrams
section for details.