Installation manual
Outer wall terminals M-WRG-II ES (-P, -PK), M-WRG-II KSR (-1, -2)
- 17 -
Meltem Wärmerückgewinnung GmbH & Co. KG
Am Hartholz 4 · D-82239 Alling
[email protected] · www.meltem.com
VENTILATION THE RIGHT WAY
V E N T I L A T I O N & H E A T R E C O V E R Y
6.2.3
Attaching the outer wall terminals
►
Carefully push the outer wall termi-
nals (item 1 in Fig. 14) onto the venti-
lation pipes (item 2 in Fig. 14). Be
careful not to damage the seals.
►
Direct the drip edges (item 3 in
►
Press each outer wall terminal
against the outer wall so that the
plastic ring (item 4 in Fig. 14) lies flat
against the outer wall. Hold the outer
wall terminal in this position.
►
Carefully screw the upper and lower
Torx screws (item 5 in Fig. 14) in as
far as they will go. They will self-tap
into the ventilation pipes, thus fixing
the outer wall terminal in position.
NOTICE
If the outer wall terminal does not lie flush against the external wall, seal the gap
between the outer wall terminal and the external wall with a bead of permanently elastic
sealant. There is a risk that the plaster will be damaged if this is not done.
►
Clean the outer wall terminal if necessary (see section 7.3 on page 18).
Fig. 14: Attaching the outer wall terminals
1
2
3
4
5
5