Installation
Rev 1.2
Mellanox Technologies
16
Figure 6: Rack Rail Kit Parts
Planning the system’s placement in the rack
Before mounting the system to the rack, select the way you wish to place the system. Pay atten-
tion to the airflow within the rack cooling, connector and cabling options.
While planning how to place the system, consider the two installation options shown in Figure 7,
and review the following points:
• Make sure the system air flow is compatible with your installation selection. It is
important to keep the airflow within the rack in the same direction.
• Note that the part of the system to which you choose to attach the rails (the front panel
direction, as demonstrated in Option 1 or the FRUs direction, as demonstrated in Option
2) will determine the system’s adjustable side. The system’s part to which the brackets
are attached, will be adjacent to the cabinet.
• The FRU side is extractable. Mounting the rack brackets inverted to the FRU side
(Option 2), will allow you to slide the FRUs, in and out.