Installation
Rev 1.1
Mellanox Technologies
27
The protective ground terminal of the WDM unit, located on the rack mount, must be connected
to a protective ground.
Figure 16: Grounding the MEX6200
2.6
Connecting the TX6240/TX6280 System to the MEX6200 Unit
To Connect the MEX6200 to the TX6240 or TX6280, perform the next steps:
Step 1.
Connect the provided Ethernet cable to the mgmt1 interface of the system on one end and the
ETH port of the MEX6200 on the other.
Step 2.
Insert the DWDM C-Band optical modules into their appropriate ports, beginning with Ch #28
to Port 1, Ch #29 to Port 3, etc.
Step 3.
Connect the ribbon cable from the MEX6200 MUX and DEMUX ports to the uplink data ports.
Make sure to connect LC1 to Port 1, LC2 to Port 3, etc. See Figure 17.
Step 4.
Clip the loose fibers of the ribbon cable.
Step 5.
Insert the SFP+ SR modules into the downlink ports of the WDM (2, 4, etc.)
Step 6.
Insert the QSFP SR4L modules into the system’s EXT ports.
Step 7.
Connect the fiber cable connector to the EXT ports on one end and to the downlink ports of the
WDM (LC1 to Port 2, LC2 to Port 4, etc).
Dangerous voltages may be present on the cables connected to the MEX6200:
•
Never connect cables to an MEX6200 unit if it is not properly installed and grounded. This
means that its power cable must be inserted in an outlet provided with a protective ground
(earth) contact before connecting any user or network cable to the MEX6200
•
Disconnect all the cables connected to the connectors of the MEX6200 before disconnect-
ing the unit’s power cable.
•
In Finland, Norway and Sweden, CLASS I PLUGGABLE EQUIPMENT TYPE A must
have the following marking text to state that the equipment must be permanently connected
to an earthed mains socket-outlet:
•
In Finland: "Laite on liitettävä suojakoskettimilla varustettuun pistorasiaan"
•
In Norway: "Apparatet må tilkoples jordet stikkontakt"
•
In Sweden: "Apparaten skall anslutas till jordat uttag"
Summary of Contents for MetroX TX6240
Page 8: ...Mellanox Technologies 8 Table 37 RJ 45 CONSOLE Pinout 72 Table 38 RJ 45 I2C Pinout 72...
Page 79: ...Rev 1 1 Mellanox Technologies 79 5 6 7 8 9 10...
Page 80: ...Mellanox Technologies 80 11 12 13 14 15 16...
Page 81: ...Rev 1 1 Mellanox Technologies 81 17 18 19 20 21 WEEE 22...
Page 83: ...Rev 1 1 Mellanox Technologies 83 7 8 9 10 InfiniBand 11 12 13 PSU InfiniBand...
Page 96: ...Mellanox Technologies 96 4 5 6 7 8 9 10 InfiniBand 45 C 113 F 8 3 InfiniBand...