FOCKE MELER GLUING SOLUTIONS
4-28
USE
ModBus communications
The unit comes with the option of an RS485 port for MODBUS RTU
communications.
The tables are as follows:
IMPUT
Register
Address
Description
MAGNITUDE
MIN
MAX
Read / Write
TYPE
30001
0
ALWAYS 0x1111
number
0
65535
R
Uint16
30002
1
Machine ID
number
0
65535
R
Uint16
30003
2
HMI Software version
number
0
65535
R
Uint16
30004
3
IO Software version
number
0
65535
R
Uint16
30005
4
Input Inhibition
number
0
1
R
Uint16
30006
5
Input Temperature OK
number
0
1
R
Uint16
30007
6
Output Error
number
0
1
R
Uint16
30008
7
Output Status
number
0
1
R
Uint16
30009
8
Digital Inputs
number
0
63
R
Uint16
30010
9
Digital Outputs
number
0
63
R
Uint16
30011
10
Analog Input 1
Volts
0
1000
R
Uint16
30012
11
Analog Output 1
Volts
0
1000
R
Uint16
30013
12
Analog Output 2
Volts
0
1000
R
Uint16
30014
13
Encoder pulses
number
0
65535
R
Uint16
30015
14
Speed
m/min
0
65535
R
Uint16
30016
15
Active Alarm
number
0
65535
R
Uint16
30017
16
Last Alarm 1
number
0
65535
R
Uint16
30018
17
Last Alarm 2
number
0
65535
R
Uint16
30019
18
Last Alarm 3
number
0
65535
R
Uint16
30020
19
Last Alarm 4
number
0
65535
R
Uint16
30021
20
Last Alarm 5
number
0
65535
R
Uint16
30022
21
Estatistics: Total product
number
0
65535
R
Uint16
30023
22
Estatistics: Partial product
number
0
65535
R
Uint16
30024
23
number
0
65535
R
Uint16
30025
24
number
0
65535
R
Uint16
30026
25
number
0
65535
R
Uint16
30027
26
number
0
65535
R
Uint16
30028
27
number
0
65535
R
Uint16
30029
28
number
0
65535
R
Uint16
30030
29
number
0
65535
R
Uint16
30031
30
Estatistics: Total product High
number
0
65535
R
Uint16
30032
31
Estatistics: Total product Low
number
0
65535
R
Uint16