FOCKE MELER GLUING SOLUTIONS
4-8
USE
6.
EDIT SELECTED INSTALLATION
screen.
6 tabs appear, one for each channel (EV). Each tab allows you to edit the
distance between the applicator of that channel and each photocell. It also
allows you to set the ON and OFF compensation times of that applicator.
STARBI.
i
EV1
EV2 EV3 EV4 EV5 EV6
FC1
0.0
FC2
0.0
FC3
0.0
FC4
0.0
FC5
0.0
FC6
0.0
On
0.0
Off
0.0
Installation 2
Distance between PC/ Aplicator (mm)
Compensation time (ms)
To ADVANCED OPTIONS screen
Depends on the number of channels configured
7.
ADVANCED OPTIONS
screen.
On the ADVANCED OPTIONS screen you can determine the encoder, the
analogue speed input and the minimum working speed at which the outputs
are activated normally. Below this speed, the outputs remain deactivated.
STARBI.
i
Encoder
Analog in
Minimun working speed
60
m/mim
Installation 2
Press to determine encoder
Press to determine analogue input
Enter minimum working speed
Press to select encoder
Press to select analogue input
!
!