MA-5151-ENG
PATTERN CONTROLLER STARBI
USE
4-17
22.
ADVANCED PARAMETERS
screen.
Other parameters can be configured in addition to the patterns. The keyboard
opens when pressing on the text boxes. After entering the value it will be
visible in the text box.
23.
REPETITIVE PRODUCT BY TIME
screen.
The screen appears when you name a new product from the NEW PRODUCT
screen or if you select an existing one from the EDIT PRODUCT screen. The
first step is to select the photocell and then edit the pattern.
B
A
W
i
5.
12.5
12.5
6.
7.
8.
1
2
3
4
5
6
P1
Product 0
Select your FC
Unidad: ms
On
0.0 mm Step
0.0 mm
A- Select photocell.
B- The pattern is defined by its initial moment (ON, beginning of
the application), and the time from one repetition to the next
(STEP).
C- The patterns are displayed as they are created or deleted,
depending on the number of configured channels 2, 4 or 6.
D- Press to add pattern (≤ number of channels).
E- Press to delete pattern (≥1). Delete the selected pattern.
F- The selected channels are in green. The channels already
selected in previous patterns are in grey and if they are free
(unselected) they will appear empty (background colour).
G- Only 4 beads (1, 2, 3, 4) appear. You can move the table with
the arrows. When pressing the DOWN arrow, beads 1, 2, 3, 4
disappear and beads 5, 6, 7, 8 appear. Press the UP arrow to
return to beads 1, 2, 3, 4.
H- Up to 8 beads for each pattern. The green switch if it is
dotting, the grey switch if it is not dotting.
I- Skip to advanced parameters screen.
I
C
F
H
D
E
A- Deactivated by default. There is no
dotting of any bead, even if the beads
have dotting activated on the parameters
screen of each pattern. Configure the
dotting according to the start time (S)
and duration (P) parameters.
B- You can configure a time during which
new detections will not be considered,
avoiding ‘false product’ situations.
C- A set value is determined for each
output.
G
STARBI.
i
Dot bead
Analog output 1
Analog output 2
Disable FC
0.0
mm.
5.5
V.
5.5
V.
P
0.0 mm.
S
0.0 mm.
Product 0
A
B
C
!
!