FOCKE MELER GLUING SOLUTIONS, S.A.
3-8
INSTALLATION
- Drum melter ready (temperatures OK-green).
- Motor running (pump rotation -amber).
- Half empty drum (blinking white).
- Empty drum (fixed white).
- Alarms (red).
Also it is possible to connect this signals to the main machine through non-
voltage external contacts.
Warning:
Risk of electric shock. Carelessness may cause injuries or death.
Temperature ok
1. If only this signal will be connected, use a 0.5 mm
2
two-wire cable.
2. Thread the power cord (max. Ø12.5mm) through the electrical wall
bushing Pg16 and fasten it to the inside anchor, making sure that the
cord reaches the power card connector.
3. Connect the two wires from the start-up signal to the terminals 15X41
and 15X42. This is a double terminal, which makes it necessary to
connect each wire in one of the two holes in the terminal. Since this
contact is not under voltage, there is no connection polarity.
4. Make sure that the cables are firmly attached by the terminal screws.
5. Make sure that the cable is well connected and that its path through
the electrical cabinet presents no risks of snagging, being cut or any
other accidental deterioration.
Warning:
It must be connected to 24 AC or DC voltage with a maximum
current of 500mA. If you connect this signal to 230V load current cannot be
less than 50mA.
External Standby
1. If this is the only signal being connected, use 0.5 mm
2
two-wire cable.
2. Open the electrical cabinet door as far as possible. Thread the power
cord (Ø4-8 mm) through the wall bushing Pg16 and fasten it to the
inside anchor, making sure that the cord reaches the power card
connector at the position where it will be installed.
3. Remove the connector from the card and connect the two cable wires
to their corresponding connector terminals:
Summary of Contents for PS200
Page 1: ...MA 5066 ENG 250220 GLUING SOLUTIONS ADHESIVE MELTER PS200 DRUM UNLOADER INSTRUCTIONS MANUAL ...
Page 8: ...FOCKE MELER GLUING SOLUTIONS TABLE OF CONTENTS This page is intentionally left blank ...
Page 34: ...FOCKE MELER GLUING SOLUTIONS S A 3 12 INSTALLATION This page is intentionally left blank ...
Page 68: ...FOCKE MELER GLUING SOLUTIONS S A 4 34 MELTER OPERATION ...
Page 75: ...ELECTRICAL DRAWINGS 7 1 MA 5066 ENG PS200 DRUM MELTER MANUAL 7 ELECTRICAL DRAWINGS ...
Page 78: ...FOCKE MELER GLUING SOLUTIONS S A 8 2 PNEUMATIC DIAGRAMS 1 2 3 4 5 6 9 8 7 11 12 10 13 14 ...
Page 80: ...FOCKE MELER GLUING SOLUTIONS S A 8 4 PNEUMATIC DIAGRAMS This page is intentionally left blank ...
Page 82: ...FOCKE MELER GLUING SOLUTIONS 9 2 SPARE PARTS LIST A STRUCTURE 7 5 4 6 2 3 9 8 1 ...
Page 84: ...FOCKE MELER GLUING SOLUTIONS 9 4 SPARE PARTS LIST B PLATEN ENSEMBLE 2 3 4 5 7 8 6 1 ...
Page 98: ...FOCKE MELER GLUING SOLUTIONS 9 18 SPARE PARTS LIST This page is intentionally left blank ...