FOCKE MELER GLUING SOLUTIONS, S.A.
3-6
INSTALLATION
• 160 °C (320 °F) for the melting platen.
• 150 °C (302 °F) for hoses and 160 ºC (320 °F) for applicators.
The general process for modifying set up temperature values for any
component is described below.
1. Select the component for which you wish to modify the value with the
left-right arrow.
The corresponding LED will blink quickly.
2. Using the up-down arrow, select the desired value for the set point
temperature.
3. After ten seconds, the LED will stop blinking and the display will
change by default to the set point temperature, saving the changed
data.
This simple process must be repeated for each one of the components
installed on the melter.
Selecting the overheating value
1. Press the buttons with the clock symbol and the down arrow at the
same time to enter the special menu.
The choice of display units (ºC or ºF) will appear on the display.
2. Using the right arrow, we advance to the next screen where the
overheating symbol appears.
3. Select the desired value with the up-down arrow.
The value displayed corresponds to the increase in real temperature
over the set point temperature permitted without activating the alarm
message.
4. Use the right arrow to advance to the next screen.
5. Exit the special menu using the left arrow and the melting platen
temperatures will once again be displayed.
All the special menu values will be saved.
Summary of Contents for PS200
Page 1: ...MA 5066 ENG 250220 GLUING SOLUTIONS ADHESIVE MELTER PS200 DRUM UNLOADER INSTRUCTIONS MANUAL ...
Page 8: ...FOCKE MELER GLUING SOLUTIONS TABLE OF CONTENTS This page is intentionally left blank ...
Page 34: ...FOCKE MELER GLUING SOLUTIONS S A 3 12 INSTALLATION This page is intentionally left blank ...
Page 68: ...FOCKE MELER GLUING SOLUTIONS S A 4 34 MELTER OPERATION ...
Page 75: ...ELECTRICAL DRAWINGS 7 1 MA 5066 ENG PS200 DRUM MELTER MANUAL 7 ELECTRICAL DRAWINGS ...
Page 78: ...FOCKE MELER GLUING SOLUTIONS S A 8 2 PNEUMATIC DIAGRAMS 1 2 3 4 5 6 9 8 7 11 12 10 13 14 ...
Page 80: ...FOCKE MELER GLUING SOLUTIONS S A 8 4 PNEUMATIC DIAGRAMS This page is intentionally left blank ...
Page 82: ...FOCKE MELER GLUING SOLUTIONS 9 2 SPARE PARTS LIST A STRUCTURE 7 5 4 6 2 3 9 8 1 ...
Page 84: ...FOCKE MELER GLUING SOLUTIONS 9 4 SPARE PARTS LIST B PLATEN ENSEMBLE 2 3 4 5 7 8 6 1 ...
Page 98: ...FOCKE MELER GLUING SOLUTIONS 9 18 SPARE PARTS LIST This page is intentionally left blank ...