MELTER OPERATION
MA-5127-ENG
MACRO FOAM SERIES MELTER MANUAL
Alarm displays
Macro Foam series melter equipment tell the user when a malfunction has
occurred in the unit, sending warning messages that may be seen on the
control panel display.
When an alarm appears, the control unit takes a series of steps to protect the
unit. Simply correct that malfunction and the control unit will reactivate the
equipment functions.
Standby function does not generate any alarm.
If a temperature sensor is broken, the system heats all the elements except
the one where the failure is located.
In case of overheating the system cuts off inmediately the damaged element.
After three minutes if the failure continues all the system will be shut down.
After repairing the failure the system starts heating normally.
Code
Source
Actions
Heating
Pump
Main machine signal
Err 0
tank broken sensor
only tank off
off
off
Err 1
distributor 1 broken sensor
only distributor1 off
off
off
Err 2
pump 1 broken sensor
only distributor2 off
off
off
Err 3
distributor 2 broken sensor
only distributor3 off
off
off
Err 4
pump 2 broken sensor
only distributor4 off
off
off
Err 5
hose 1 broken sensor
only hose1 off
off
off
Err 6
applicator 1 broken sensor
only applicator1 off
off
off
Err 7
hose 2 broken sensor
only hose2 off
off
off
Err 8
applicator 2 broken sensor
only applicator2 off
off
off
Err 9
hose 3 broken sensor
only hose3 off
off
off
Err 10
applicator 3 broken sensor
only applicator3 off
off
off
Err 11
hose 4 broken sensor
only hose4 off
off
off
Err 12
applicator 4 broken sensor
only applicator4 off
off
off
Err 13
premelter broken sensor
only premelter off
off
off
Err 100
tank overheating
all components off
off
off
Err 101
distributor 1 overheating
all components off
off
off
Err 102
pump 1 overheating
all components off
off
off
Err 103
distributor 2 overheating
all components off
off
off
Err 104
pump 2 overheating
all components off
off
off
Err 105
hose1 overheating
all components off
off
off
Err 106
applicator1 overheating
all components off
off
off
Err 107
hose2 overheating
all components off
off
off
Err 108
applicator2 overheating
all components off
off
off
Err 109
hose3 overheating
all components off
off
off
Err 110
applicator3 overheating
all components off
off
off
Err 111
hose4 overheating
all components off
off
off
Err 112
applicator4 overheating
all components off
off
off
Err 113
premelter overheating
all components off
off
off
Summary of Contents for MACRO FOAM Series
Page 1: ...MA 5127 ENG 231220 GLUING SOLUTIONS ADHESIVE MELTER MACRO FOAM SERIES INSTRUCTIONS MANUAL ...
Page 8: ...FOCKE MELER GLUING SOLUTIONS TABLE OF CONTENTS This page is intentionally left blank ...
Page 34: ...FOCKE MELER GLUING SOLUTIONS S A 3 14 INSTALLATION This page is intentionally left blank ...
Page 75: ...ELECTRICAL DRAWINGS 7 1 MA 5127 ENG MACRO FOAM SERIES MELTER MANUAL 7 ELECTRICAL DRAWINGS ...
Page 78: ...FOCKE MELER GLUING SOLUTIONS S A 8 2 PNEUMATIC DIAGRAMS This page is intentionally left blank ...