FOCKE MELER GLUING SOLUTIONS, S.A.
3-4
INSTALLATION
Electrical power connection
Macro Foam series melters are designed to be connected to the electrical
power supply in 3-phase 400 VAC with neutral.
A good ground connection is required in any case.
Consumption figures, according to melter and output configuration, are
included in the table.
Warning:
Risk of electrical shock. Carelessness may cause injury or death.
Install the electrical wall bushing Pg 21 in the area reserved for them,
fastening them to the plate with the appropriate nut.
Open the electric cabinet door as far as possible. Thread the power cord (Ø14-
18 mm) through the electrical wall bushing Pg 21 and fasten it to the inside
anchor, making sure that the cord reaches the power terminals block inside
the cabinet.
Connect each wire in the power cord to its corresponding place on the power
terminals block, as shown in the figures.
Unit
No. outputs
3 Phases
400 VAC Y
1 Single Pump
Macro Foam 35
2
20.5 A
4
20.5 A
Macro Foam 50
2
21.3 A
4
23.7 A
Macro Foam 120
2
26.3 A
4
31.6 A
Pg21
R
R SS TT N
N
L1 L2 L3 N PE
3N ~ 400V 50Hz + PE
Summary of Contents for MACRO FOAM Series
Page 1: ...MA 5127 ENG 231220 GLUING SOLUTIONS ADHESIVE MELTER MACRO FOAM SERIES INSTRUCTIONS MANUAL ...
Page 8: ...FOCKE MELER GLUING SOLUTIONS TABLE OF CONTENTS This page is intentionally left blank ...
Page 34: ...FOCKE MELER GLUING SOLUTIONS S A 3 14 INSTALLATION This page is intentionally left blank ...
Page 75: ...ELECTRICAL DRAWINGS 7 1 MA 5127 ENG MACRO FOAM SERIES MELTER MANUAL 7 ELECTRICAL DRAWINGS ...
Page 78: ...FOCKE MELER GLUING SOLUTIONS S A 8 2 PNEUMATIC DIAGRAMS This page is intentionally left blank ...