FOCKE MELER GLUING SOLUTIONS, S.A.
3-2
INSTALLATION
Electrical Consumption
In order to install a Macro Foam series melter, we should take into
consideration the total consumption of the installation, including the
consumption of the installed hoses and applicators.
Before connecting, make sure that the voltage that is being connected to the
melter is the correct one appearing on the equipment’s characteristics plate.
Connect the machine and check to see if it is well grounded.
Warning
: Risk of electrocution. Even when the equipment is turned off,
voltage remains in the intake terminals, which may be dangerous during
internal equipment manipulations.
Install a power switch for disconnecting the melter equipment from the
electrical network. It must be protected against overload and short circuits by
circuit breaker and install appropriate personal protection leads to mass by
differential switch.
Consumption figures, according to melter and output configuration, are
included in the table in the section ‘Electrical power connection’.
Compressed air
As an option, a pneumatically activated by-pass valve may be installed. If this
is added to the system, a dry, unlubricated compressed air network must be
available, with a maximum pressure of 6 bar.
The by-pass valve consumes next to no air, given that this is a pressurized
closed circuit.
Other factors
While installing Macro Foam series melters, other practical considerations
should be kept in mind:
Item
Description
Dimensions
35 L / 50 L
120 L
A
DOOR OPENED
430 mm
795 mm
B
ELECTRICAL CABINET DISPLACEMENT
410 mm
C
UNIT LENGTH
1150 mm
1150 mm
D
UNIT LENGTH WITH FREE SPACE TO RIGHT SIDE DEVICES ACCESS
2080 mm
E
UNIT HEIGHT
1825 mm
1825 mm
F
UNIT WIDTH
510 mm
875 mm
G
UNIT WIDTH WITH FREE SPACE TO REAR SIDE DEVICES ACCESS
1510 mm
1875 mm
Summary of Contents for MACRO FOAM Series
Page 1: ...MA 5127 ENG 231220 GLUING SOLUTIONS ADHESIVE MELTER MACRO FOAM SERIES INSTRUCTIONS MANUAL ...
Page 8: ...FOCKE MELER GLUING SOLUTIONS TABLE OF CONTENTS This page is intentionally left blank ...
Page 34: ...FOCKE MELER GLUING SOLUTIONS S A 3 14 INSTALLATION This page is intentionally left blank ...
Page 75: ...ELECTRICAL DRAWINGS 7 1 MA 5127 ENG MACRO FOAM SERIES MELTER MANUAL 7 ELECTRICAL DRAWINGS ...
Page 78: ...FOCKE MELER GLUING SOLUTIONS S A 8 2 PNEUMATIC DIAGRAMS This page is intentionally left blank ...