Instructions Manual
6.Connection
6-1.Overview of Connection Configuration
DC Power Supply
DC+24V
0V(GND)
User
GDB-5F40
Controller
Twisted
J3 1 2 3 4 5
J2 1 2
pair wire
J1
CWP
CW+
CWP
CW-
CCWP
CCW+
CCWP
CCW-
+COM
M.F+
M.F
M.F-
P.O
P.O
R.GND
R.GND
O.H.A
O.H.A
R.GND
R.GND
+COM
C.S+
C.S
C.S-
●Connect only one motor to one driver.
●Do not power ON/OFF by the relay etc. in the output side of the DC power supply.
●Use twisted pair wire for the CW/CCW input signal line.
●Provide shielding for the signal line where considerable noise is generated.
●Use the wire material of the characteristic that is difficult to burn.
●Provide shielding for the motor line if it generates significant noise.
●For the driver's power supply, use a DC power supply with reinforced insulation
on its primary and secondary sides.
〔Example configuration〕
The metallic enclosure and shielded wires work to shield noise.
Metal Enclosure
Metal Enclosure
Metal Enclosure
User
Controller
7
8
9
GDB-5F40
1
2
3
4
5
10
11
12
6
DC+
DC-
MOTOR
MOTOR
Shield
Shield
Grounding
Grounding
Grounding
-22-
Summary of Contents for GDB-5F40
Page 31: ...Instructions Manual 10 2 I O Signal 1 Example Circuit Connection 31 ...
Page 37: ...Instructions Manual 10 3 Dimensions Unit mm 37 ...
Page 40: ...Instructions Manual 40 ...
Page 41: ...Instructions Manual 41 ...
Page 42: ...Instructions Manual 42 ...
Page 43: ...Instructions Manual 43 ...
Page 44: ...Instructions Manual 44 ...