GD-5410v1
Instructions Manual
10.Specifications
10-1.General Specifications
Single-phase 100-115V(50/60Hz) *1
●Rated power at DRIVE:
〔DRIVE I.SEL ⇒ No.F set up〕*2
AC100V : 2.6A
AC115V : 2.6A
●Rated power at HOLD:
〔DRIVE I.SEL ⇒ No.F, HOLD I.SEL ⇒ 40% set up〕
AC100V : 0.3A or less AC115V : 0.3A or less
●DRIVE CURRENT 0.35A/phase~1.8A/phase (16 levels)
●HOLD CURRENT 10%~100% of DRIVE CURRENT (16 levels)
●Drive pulse input
(CW, CCW)
Photo-coupler input
●Motor excitation stop input
(M.F)
Photo-coupler input
●Step angle switch input
(C.S)
Photo-coupler input
●Phase signal output
(P.O)
O/C output
●Overheat alarm signal output
(O.H.A)
O/C output
●DRIVE CURRENT selection (DRIVE)
●PULSE INPUT TYPE selection (SPI)
●HOLD CURRENT selection (HOLD)
●HOLD SWITCHING TIME selection (DHT)
●STEP ANGLE selection (STEP)
●ROTATE CHARACTERISTIC selection (RC)
●MOTOR selection (OP1,OP2)
Indoor (Exposure to direct sunshine is not allowed.)
Without any explosive, corrosive or inflammable gas, oil mist, or dust
(At ordinary temperature and humidity)
*1
Input voltage range is single-phase 100-115V±10%.
*2
Power demand varies with rotation speed, a load, etc.
*3
Including screws and terminal blocks.
AC terminal - signal terminal
Insulated
Withstanding Voltage
1500VAC: for one minute
500VDC: 100MΩ or more
Atmosphere
Altitude
Up to 1000m above sea level
(No freezing allowed)
Withstanding
Vibration
No abnormality should be found after a vibration test
at 10~55Hz, 0.15mm P-P.
Exterior Dimensions
H
124.5 ×
W
130 ×
D
55.5 (mm) *3
0.55 kg
500VDC: 100MΩ or more
Weight
Insulation Resistance
1500VAC: for one minute
Supply Power
(No freezing allowed)
Input Signal
Output Signal
Operating Ambient
Temperature
0℃ ~ +50℃
Motor output current
Function of Operating
Sections
80%RH or less
-10℃ ~ +60℃
80%RH or less
(No condensation allowed)
Operating Ambient
Humidity
Storing Temperature
Storing Humidity
(No condensation allowed)
-32-