GD-5410v1
Instructions Manual
6-2.Connecting Signal I/O Connector(J1)
The following items are required:
● Housing for J1 (51103-1200:Molex):
One unit (accessory)
● Contact for J1 (50351-8100:Molex):
12 contacts (accessories)
● Manually operated crimping tool
for AWG28-22(57295-5000:Molex):
One unit
(1) Crimp the contact to the cable used for wiring.
(2) Insert the contact into the housing.
Make sure that the housing No. and the connector No. on the main frame are
matched before inserting the contacts.
(3) Connect the housing to the connector on the main frame.
● The contacts for J1 are 12 pieces.
● When inserting, keep pushing J1 housing into the connector until it is
locked. Also, check if the contacts are not displaced from the housing.
● In wiring, isolate the J1 signal lines from equipment that may be
さい。
a source of noise, the power line and the motor line.
(Surface on which the contacts are inserted)
Housing for J1
GD-5410v1
● Use a signal cable of AWG26(0.15mm
2
) or more in diameter.
12 11 10 9
8
7
6
5
4
3
2
1
CWP
J1
CW+
R.GND
User
controller
CCWP
+COM
+COM
R.GND
C.S
O.H.A
P.O
M.F
CCWP
CWP
CW-
CCW+
CCW-
M.F+
M.F-
C.S+
P.O+
O.H.A+
Step angle
switch input
〈Wiring〉
〈Crimping〉
〈Connection〉
〈Insertion〉
Contact
Housing
1
2
3
4
5
6
7
8
9
10
11
12
1
2
3
4
5
6
7
8
9
10
11
12
C.S-
Overheat alarm
signal output
Phase signal output
Motor excitation
stop input
Drive pulse input
Drive pulse input
P.O-
O.H.A-
-23-