4-6.Setting PULSE INPUT TYPE SELECT switch
Erroneous setting may cause breakage of
the machine or injury due to unexpected
rotation of motor.
Ensure correct setting.
2-pulse input method / 1-pulse input method are
set up by the 〔SPI〕switch.
The new setting of the function setting switch
will become effective after the power is cycled.
(1) Set the 〔SPI〕switch.
● When the motor is operated with two pulse signal inputs of CW and CCW,
set the SPI switch to [OFF].
● When the motor is operated with the pulse signal and direction signal
input, set the SPI switch to [ON].
● In the case that 1-pulse input method is selected, the CCW terminal becomes
direction signal input designating the direction of the motor rotation.
Drive pulse set to the CW terminal(CW+,CW-).
● The input timing is same with 2-pulse input method and 1-pulse input method .
As for input timing, refer to "10-3. (2)Drive pulse input(CW, CCW)"
4-7.Setting MOTOR SELECT switch
Erroneous setting may cause burn on the
skin due to overheating of the motor.
Ensure correct setting.
The OP1 and OP2 switches is turned to the setting
corresponding to the motor in use.
(1) Set the OP1 and OP2 switches to the specified in the talbe
'10-5.Applicable Motors'.
(Factory Setting)
SPI
Input type
1PULSE (1P)
2PULSE (2P)
ON
OFF
CCW terminal(CCW+,CCW-)
direction set
Photo-coupler OFF: CCW direction
Photo-coupler ON : CW direction
CAUTION
CAUTION
-19-