Instructions Manual
4.Function Set-up by Use
4-1.Setting MOTOR SELECT switch
Erroneous setting may cause burn on the
skin due to overheating of the motor.
Ensure correct setting.
The MOTOR SEL switch is turned to the setting
corresponding to the motor in use.
Set this switch with power OFF.
The switch is factory-set to [10L].
(1) Turn power [OFF].
(2) Turn switch [10L/5L] to the setting specified in the table "10-5. Applicable Motors."
4-2.Setting STEP ANGLE SELECT switch
Erroneous setting may cause breakage of
the machine or injury due to unexpected
rotation of motor.
Ensure correct setting.
The step angle is set up with the STEP SEL switch.
The step angle can be selected from five different
types of step angles.
The switches are factory-set to [1/20 divisions].
(2)
Set the STEP SEL switch [SA,SB,SC] to the step angle required.
●Relationship between the STEP SEL switch and the step angle.
(Factory setting)
1/4
1/10
1/20
SA
ON
OFF
ON
OFF
ON
0.18
0.072
0.036
SB
Number of
Divisions
Step angle(°)
0.72°motor
0.72
0.36
STEP SEL switch
SC
1/1
1/2
ON
ON
ON
ON
OFF
OFF
ON
OFF
ON
ON
I
I