![Melec ADB-5431 User Manual Download Page 13](http://html1.mh-extra.com/html/melec/adb-5431/adb-5431_user-manual_1767079013.webp)
Instructions Manual
3-5.Operation Section
ADB-5431
〔2P〕
Selects a pulse input type.
SC:〔OFF〕
MOTOR
SELECT switch
Selects the applicable motor.
〔10L〕
SA:〔ON〕
STEP ANGLE
SELECT switch
Selects a step angle.
SB:〔ON〕
HOLD CURRENT
ADJUSTMENT trimmer
Adjusts HOLD CURRENT.
〔Approx. 40%〕
DRIVE CURRENT
SELECT switch
Selects DRIVE CURRENT.
〔IH〕
Name of Operation Section
Function
Factory
Setting
HOLD SWITCHING TIME
SELECT switch
DRIVE/HOLD CURRENT automatic switching time
is selected.
〔DH1(150ms)〕
PULSE INPUT TYPE
SELECT switch
ROTATE CHARACTERISTIC
SELECT switch
Selects a characteristic of motor rotation.
〔RC2〕
-13-