12616, Rev. B
17. Self-diagnosis Mode
53
(13)Display of the test results
(1) When [SUMMERY of TEST] is displayed, press the ENTER key to see all the diagnosis results.
[* KEY PANEL:OK ]
(2) NC means No Check. An item which have not been diagnosed are indicated by the following
message.
[*XXXXXXXX:NC ]
(14)Individual diagnosis
You can select desired item and carry out individual diagnosis.
(1) To enter individual diagnosis mode, press ALT+ ENTER keys while the diagnosis results are
displayed.
[#XXXXXXXXXX ]
(2) Press the MENU key to select an item for diagnosis.
[# XY SENSOR ]
(3) Press the ENTER key.
[REAR (Ans=H):H ]
In this step, when the MENU key is pressed, you can exit from the individual diagnosis for the
item in the following steps, the same procedure as the above operations are carried out. In the
individual diagnosis mode, when ALT+ENTER keys are pressed, the machine goes to the display
mode for the diagnosis results. The results of the diagnosis will be displayed.
* For example, if you only want to diagnose initialization sensor, press any key so that the result
will be judged "NG (No Good, or Failure.)" and go to the display mode for the test results. Press
the ALT+ENTER keys to enter the individual diagnosis mode and carry out the initial setting
sensor’s diagnosis.
(15) Data confirmation of EEPROM
In individual diagnosis, there is an item for data confirmation of EEPROM.
(1) In individual diagnosis mode, press the MENU key. You can select the item of the confirmation
for the EEPROM.
[# READ EEPROM ]