M2i-LAN Laser-Scanner manual
HB-M2-iLAN-UDP-E.doc
page 8 of 44
MEL Mikroelektronik GmbH, Breslauer Str. 2, 85386 Eching / Germany
www.MELSensor.de
Technical Data
Profiles update rate
max. 93.5 Hz
Profile rate, Trigger-Mode
approx. 60 Hz
Profile rate, external synchronized
max. 93.5 Hz
Stability of time base
100 x 10
-6
Min. / Max. Environment temperature
min. 0°C (+ 32°F)
max. 40°C (+ 95°F)
Min. / Max. Storage temperature
min. –30°C (+ 2°F)
max. 75°C (+ 167°F)
I
I
n
n
t
t
e
e
g
g
r
r
a
a
t
t
e
e
d
d
e
e
l
l
e
e
c
c
t
t
r
r
o
o
n
n
i
i
c
c
s
s
y
y
s
s
t
t
e
e
m
m
Supply current
120 mA at 24 V; Laser on
Range of supply voltage
+ 10 ... 30 V DC
Digital inputs
Low = 0 ... 2 V High = 5 ... 30 V
Weight
300
g
Dimensions
102 mm x 74 mm x 27,5 mm
Mounting
holes for 4 x M5 screw
connections
12 pin round female for Scanner head
M12 - 8 Pin male supply and controls
Synchronization and external Trigger
M12 4 Pin female = Ethernet D coded
RJ-45-Ethernet internal for service
Protection
class
IP
65
Vibration: the electronic unit has been specially protected against shock and vibration.
Encoder signal connection
Encoder-Data is received at the digital inputs at the control connector. The encoder information is read and
transmitted embedded in the profile information over TCP Ethernet connection. The encoder data is always
in sync to the profile relating to this encoder data.
RS-232 interface for diagnosis and firmware update
Baud rate: Monitoring
115. 200 Baud
Baud rate: Firmware-Update
57.600 Baud
The RS 232 interface does not carry profile data or scanner control information.
Software:
the current release of the MEL „EthernerScanner.exe“ Demo- and configuration software is
available as download from MEL FTP-Server:
. Call MEL hotline for further details.