Register 

HEX/DEZ 

Bit 

Function register 
(marked light blue) 

Remarks  

0x0 

6..0 

Shutter time Low 

0x1 

2..0 

Shutter time High 

Shutter time 
0 = max 1022 = min  1023 = Laser off 

Manual control 

0x2 

6..0 

Max shutter time Low 

0x3 

2..0 

Max shutter time High 

Limit for max. shutter time an.  
0 = max  1022 = min;  for alt. Sync P 130  

Automatic control  

0x4 

6..0 

Begin pixel readout 

0x5 

6..0 

End Pixel readout 

The range is  0 … 127.    1 Bit corresponds to 8 Pixel 
condition: (Begin < End) Max is automatically limited 

0x6 

6..0 

Video gain Low 

0x7 

2..0 

Video gain high 

0 = +6 dB      1023 = +40 dB               (default = 400   ...  dB) 
Value is transferred only after sending high 

0x8 

6..0 

Intensity threshold 

1 – 127; Intensity threshold for the internal laser control 
Default  = 15 

0x9 

6..0 

Laser value 

1 – 127 value for Laser control      (default = 95) 

0xA 

10 

6..0 

Peak width Limit 

0 = 0ff; other = Peak width Limit, max. = 127 Pixel 

0xB 

11 

FPGA OK LED 

0 = on  1 = off 

0xE 

14 

Reset Position counter 

The counter is set to 0 

0xF 

15 0 

Synchronization 

0=simultaneous 

measurement 1=alternating measurement 

0x10 

16 

set Scan profile, image complete 

0=Scan profile data, 1=complete image (see page 22) 

 
0x11 

 
17 

 
5..0 

 
Sensor adjustment 
Status messages 
 
(marked yellow) 





4,5,6,7,8 
9,10,11 
12 
13 
14 
 
31..15 
63..32 

= Sensor temperature 
= Register contents 
= Version number electronic system 
= Version number camera 
= operating hours counter in 0,25 Seconds-Ticks 
= on counter 
= inputs 1 + 2 + Bit for Sensor with mirror 
= Bit 2 … 9 of Laser control 
= Version number example: 3.5xxxx 
   xxxx is the version number 
= NC 
= 32 Byte Eprom-Data (see below) 

0x12 

18 

2..0 

Set protocol version 

0 = Version1 /   1 = Version2 /   2 = Version3 /  3 = Version 4 

0x13 

19 

Reset camera chip 

Image counter and camera were reset 

0x14 

20 2..0 


5 ..4 

Do not use! 
Trigger mode | continuous 
Definition field mode 

 
0 = continuous 1 = single shot with trigger 
00 = both fields| 01=only 1

st

  field | 10 = only 2

nd

 field 

0x15 

21 

Shutter control mode 

0=automatic, 1=extern / manual (Register 0 & 1) 

0x16 

22 0 

Linearization 

0=off, 1=on; Start value 1 

0x17 

23 

0…1  Control of M20D-XF 1.000 Hz 

0 = 300 Hz; 1 = 500 Hz; 2 = 700 Hz; 3 = 1.000 Hz 

0x18 

24 

 

Special register for ISA Hardware Read out Status register        

 

 do not use with Ethernet-Hardware!

 

0x19 

25  

Not 

used 

 

0x1B  27 

6.. 0  Threshold of Profile recognition 

Default = 10    Max = 127 = 50% of maximum  description: p. 
22 

0x1C  28 

Reset FIFO 

Clear FIFO is erased 

0x1D  29 

Single shot in Trigger mode 

Register 0x14 must be set to make this function available 

0x1E  30 

Reset Sensor 

All register values were reset 

0x1F  31 

Reset Ethernet module 

Ethernet module restarts 

0x20 

32 

Watch-Dog Test 

Watch-Dog  resets Ethernet Module 

0x21 

33 

Information telegram from 
Ethernet module 

32 Re 32 Eprom values are sent. 
The transmission protocol version is 0x10 

0x22 

34 

Save new network settings 

See Manual page 14 and following. 

0x23 

35 

Ethernet Trigger mode  

0= deactivate 1= activate 

when active, read out picture with 

accessing to register 0x1D

 

0 = deactivate 1 = ac 5 Byte Data 
Command Active

Image  1.shutter 

2.shutter 

0x24 0x81 

0x80+xx 

1.st 

field 2.nd 

 

1.st  2.nd 

0x24 

36 

 

Set HDR mode 
Dual shutter operation 

Detailed description on page 22. 

0x25 

37 

 

Not used 

Do not use! 

0x26 

38 

 

MEL internal register 

Do not use! 

0x27 

39 

 

Not used 

Do not use! 

0x28 

40 

 

Not used 

Do not use! 

0x29 

41 

 

Eprom command Register 

MEL internal register – do not use!   
0 = deactivated 

Summary of Contents for M2-iLAN Series

Page 1: ...ROELEKTRONIK GMBH Intelligente Sensoren Mess Systeme M2 iLAN Laser Scanner M2D Laser Scanner with integrated Ethernet Interface TCP UDP User Manual MEL Mikroelektronik GmbH Breslauer Str 2 D 85386 Ech...

Page 2: ...ating modes 13 External Trigger Hardware Trigger 13 Synchronization 13 Ethernet Trigger 13 Digital inputs 13 UDP transmission mode 14 How to set UDP transmission mode 14 Data format and interface desc...

Page 3: ...rdware Revision 4 0 with M12 connectors FPGA Firmware Revision 4 6 Controller Firmware Revision 2 0 59 This manual describes the installation of the scanner hardware and the use of MEL demo and calibr...

Page 4: ...on software Connections E Et th he er rn ne et t H Ha ar rd dw wa ar re e Standard Ethernet components never have shown problems in the data transmission of the Ethernet scanners Network connection Rx...

Page 5: ...of the network cards like setting of the MTU Maximum Transfer Unit and accordingly load in the network causes that the 2048 Bytes will not be transferred in one packet but segmented into two packets...

Page 6: ...d IEEE 802 3af S St ta at tu us s L LE ED D s s Status LED s Meaning color OK when Power Power OK Green LED is lit Eth Link Ethernet Link in Function Yellow Blinking 100 Mbit Ethernet Link Activity Or...

Page 7: ...9 Connector M12 4pin D coded 90 angle screw on clamps Eth Con D W M12 i 550 018 10 Connecting cable M12 male 4 pin RJ 45 1 m Eth Cbl M M12 RJ45 i 550 026 11 Connecting cable M12 female 8 pin at angle...

Page 8: ...head M12 8 Pin male supply and controls Synchronization and external Trigger M12 4 Pin female Ethernet D coded RJ 45 Ethernet internal for service Protection class IP 65 Vibration the electronic unit...

Page 9: ...ner communicates with the outer world using port address IP address and a valid subnet mask A Gateway is ignored the scanner opens a peer to peer connection Therefore the set up of these communication...

Page 10: ...ss Scanner 9 192 168 124 228 different network segment Address Network card 192 168 123 199 The subnet mask for all Scanners and the network card 255 255 255 0 Do not get mixed a subnet mask 255 255 0...

Page 11: ...r screen or four small screens simultaneously The colors of the profiles can be adjusted by defining RGB values in the settings ini file Function groups are selected with the Tabs 1 16 The important T...

Page 12: ...on register 0x11 status register 2 Byte 12 page 15 and following pages P Pi ix xe el la au us sl le es se en n L Li im mi it t o of f s sc ca an nn ne er rs s v vi ie ew wi in ng g a ar re ea a The fu...

Page 13: ...ig gg ge er r H Ha ar rd dw wa ar re e T Tr ri ig gg ge er r At Pin 6 Sync in the leading edge of the trigger pulse makes the trigger event The signal should not oscillate The Sync input is an optic...

Page 14: ...er the values Scanner IP the working TCP IP left UDP destination IP enter here the target IP and port where the UDP packets shall be sent TCP port can be 3000 or any other port number UDP port can be...

Page 15: ...Mask Customer specific 44 47 Lip unsigned char 4 Working IP Address Customer specific 48 49 Tcp unsigned char 2 Working TCP Port Customer specific 50 51 Reserve unsigned char 2 Reserved 52 59 null_8...

Page 16: ...mage number 1 Byte 63 63 Scanner Status 2 1 Byte Header 64 65 Reserve 2 Byte 66 97 0 31 Status Register 32 Byte 98 129 32 63 Eprom Data 32 Byte 130 x Firmware Version String 0x00 0xFF X 1 x 32 0 30 Fu...

Page 17: ...number example 3 5xxxx xxxx is the version number NC 32 Byte Eprom Data see below 0x12 18 2 0 Set protocol version 0 Version1 1 Version2 2 Version3 3 Version 4 0x13 19 Reset camera chip Image counter...

Page 18: ...egisters Except Registers which act as impulse switch like Reset Sensor unused Registers and Bits give back a 0 31 7 0 Status Register Status messages are selected with Register 17 123 7 0 FIFO number...

Page 19: ...lu ue e 2 2 3 3 V Ve er rs si io on n n nu um mb be er r e el le ec ct tr ro on ni ic c s sy ys st te em m a an nd d c ca am me er ra a Reg value Bit Nr Meaning 2 7 0 Version electronic system example...

Page 20: ...ecial value we recommend the following procedure 1 set the Scanner in automatic mode on the target surface 2 read out Bit 2 9 from status register 3 set Scanner in manual controlled external mode 4 wr...

Page 21: ...ange not linear 56 57 6 0 LB 6 0 HB Maximum value for Measurement range not linear 58 59 6 0 LB 6 0 HB Maximum value for Scan range not linear 60 0 1 2 3 6 4 0 Half frame camera 1 full frame camera 0...

Page 22: ...serIntensity Lo Byte X 0x7F 0x80 this sends the value 101 For switching off two Bytes are ok 24h 80h Tipp for activating of the function the command must be sent in complete length 24h 81h 80h 87h D4h...

Page 23: ...sensors T Tr ri ig gg ge er r M Mo od de e Trigger mode must be activated in the register 0x14 Bit 3 with a 1 Hardware trigger is made with a leading edge of the sync input pin 15 Software trigger is...

Page 24: ...1C 02 00 04 00 01 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 70 05 22 02 08 77 18 00 12 04 58 04 2C 02 10 03 7F 1F 7F 1F 00 00 04 00 3C 17 47 04 02 7F 7F 01 Version v 2 0 55 090306 TCP UDP 15...

Page 25: ...ocation using the Web Browser H Ho ow w t to o s se et t t th he e I IP P a ad dd dr re es ss s o ov ve er r t th he e W We eb b In your Web Browser enter the IP address of the Scanner The screenshot...

Page 26: ...ote PC connected over Ethernet to the Scanner o RIP mode not set o Programming mode not set please note the default IP address can not be changed Factory setting for the working IP address on delivery...

Page 27: ...e screenshot below as an example The files in the screenshot below are the files you may need for the update procedure Flashm16 exe executable updater M2d_eth_2 0 55 firmware binary Start bat batch fi...

Page 28: ...figuration software Ethernet Scanner 2009 Release date 26 Jan 2009 and have a valid Firmware file for the version of scanner hardware in use The prog switch must be set as described in the chapter bef...

Page 29: ...and PC are in the same network subnet Check Gateway IP PC and Scanner must be in the same logical network segment Connection to PC works yet several seconds of delay in the scan profile Connection or...

Page 30: ...s not possible to read the registers Dual registers the value is active only when the high byte has been transferred Bit order register data register data Lo Byte Lo Byte Hi byte Hi byte 76543210 7654...

Page 31: ...ctronic box These values are stored until next reset command 0x1F Reset Ethernet in memory 4 examples of accessing registers functions and data These examples have been taken from the M2Dmini c For us...

Page 32: ...t cnt while cnt inp inf ioPort 2 M2DWrite write to M2D Register anz 0 registerNr command e g 0x1C reset FIFO value not used 1 write value to registerNr 2 write value to registerNR registerNr 1 shift v...

Page 33: ...syncCnt 0 tryCnt 0 while 1 val ByteFromM2 inf if val 1 return 1 timeout if val 0 synCnt else if synCnt 8 ifdef M2D_DEBUG if synCnt 8 ifdef __RT__ printk n d n synCnt else printf n d n synCnt endif end...

Page 34: ...n 1 v1 ByteFromM2 inf if v1 1 return 1 v2 ByteFromM2 inf if v2 1 return 1 v3 ByteFromM2 inf if v3 1 return 1 x i v0 v1 0x60 2 v3 0x07 9 z i v2 v1 0x1F 7 v3 v3 0xF8 intensity i v3 128 v3 127 1 v3 127 1...

Page 35: ...avoid trigger mode return 0 ok 1 fail inf sync 3 status int M2DStatus M2DInfo inf int num int i res result int res M2DStatus sens 3 result 1 M2DWrite inf 0x11 num 1 select status register M2DWrite inf...

Page 36: ...w opt1 if res 0 break if hw opt1 8 0 hw amb 10 f hw mb 10 f hw sbAmb 10 f hw abEmb 10 f res MwDStatusInt inf 48 2 hw maxZ if res 0 break res MwDStatusInt inf 50 2 hw maxX if res 0 break res MwDStatusI...

Page 37: ...data scan uiBufferUARTTx 2 scanner 0x07 uiBufferUARTTx 3 Scanner_data scan uiBufferUARTTx 0xFF uiBufferUARTTx scanner 31 0x80 scanner 17 Temperatur abfragen For y 0 y 31 y scanner y 0x80 Scanner_data...

Page 38: ...a different shutter value full frame switching mode Example of a sequence B1 shutter value 1 B2 shutter value 2 Between both shutter values for EACH field is switched 24h 81h 80h 87h D4h 80h E5h B1 9...

Page 39: ...the two functions closesocket and WSACleanup at the end E Ex xa am mp pl le e C C u us si in ng g W Wi in nS So oc ck k a an nd d S Sc ca an nn ne er r f fu un nc ct ti io on ns s receiving block siz...

Page 40: ...disrupted make sure to establish new connection bRunRead FALSE bRunConnect FALSE closesocket sTCP else here are the received data the total number of received data is in dwReceived finally free up the...

Page 41: ...t tr ra an ns sm mi is ss si io on n p pr ro ot to oc co ol l chTemp 0 0x22 command chTemp 1 0x55 command chTemp 2 0xAA command chTemp 3 0x55 command chTemp 4 0xAA command chTemp 5 0x55 command chTem...

Page 42: ...Buffer DWORD dwBuffer This function checks the protocol version and unpacks the data accordingly void CUDPScannerDlg ScannerViewScan unsigned char ucBuffer DWORD dwBuffer DWORD dwStatus DWORD dwModus...

Page 43: ...sticker stating the maximum laser power and laser safety class The scanner has a optic system dispersing the laser energy the line projector distributes the laser energy to an angle of 20 or 30 This...

Page 44: ...l other laser parameters and controls are the same These products will be equipped with a special label defining the wavelength E En nv vi ir ro on nm me en nt t S Su un nl li ig gh ht t When installi...

Reviews: