MEITRACK T366 User Guide
Copyright © 2018 Meitrack Group All rights reserved. - 20 -
Invalid: open collector
Maximum voltage for output open collector (invalid): 60 V
Maximum current for output low level (valid): 500 mA
Set the PWM output (output time and adjustable pulse width).
Connect to an external relay to remotely cut off the vehicle fuel cable or engine
power supply.
Note: Output 1 is regarded as a fuel/power cut-off output for a vehicle theft
alert by default.
7 (1-wire interface)
Green
Connect to the iButton and other devices supporting 1-wire protocol.
The port can be set to negative input 4 or output 2 open collector.
8 (5 V output cable)
Pink
5 V output
It can be connected to the power supply of a temperature sensor.
The buzzer should be connected to 5 V power supply. If it connects to more
than 12 V power supply, the device may be damaged due to large current.
The I/O cable of T366 RS232 version is an 11-pin cable. Besides the above 8 pins, there are the following 3 pins.
9
GND
10
RS232-Tx
11
RS232-Rx
Pin Number
Color
Description
9 (GND)
Black
Ground wire
10(RS232-Tx)
Purple
The device sends data through RS232 port.
11(RS232-Rx)
Brown
The device receives data through RS232 port.
8.1.2
Wiring Diagram
T366 standard version: