2.4 Pulse and frequency outputs

Page 3

2.4 Pulse and frequency outputs

The pulse generator of PTP270PEX contains three independent channels (PPO0, PPO1, PPO2). These TTL

outputs can be mapped to pins at the 9-pin connector at the rear slot cover by using a DIL switch. The pulse

outputs are able to provide a pulse per second (PPS) or a 10MHz standard frequency. They are congured by

the monitor program.

2.5 Time capture inputs

The board provides two time capture inputs called User Capture 0 and 1 (CAP0 and CAP1) which can be mapped

to pins at the 9 pin connector at the rear panel. These inputs can be used to measure asynchronous time events.

A falling TTL slope at one of these inputs lets the microprocessor save the current real time in its capture buer.

From the buer, an ASCII string per capture event can be transmitted via COM1 or displayed using the monitoring

program. The capture buer can hold more than 500 events, so either a burst of events with intervals down to

less than 1.5 msec can be recorded or a continuous stream of events at a lower rate depending on the transmission

speed of COM1 can be measured. The format of the output string is described in the technical specications at

the end of this document. If the capture buer is full a message "** capture buer full" is transmitted, if the

interval between two captures is too short the warning "** capture overrun" is being sent via COM1.

2.6 Asynchronous serial port

An asynchronous serial interface (RS232) COM0 is available to the user via a submin-D connector in the rear

panel slot cover. In the default mode of operation, the serial output is disabled until the module has synchronized

it`s internal time base to a PTP Grandmaster. However, it can be congured to be enabled immediately after

power-up. The monitoring program can be used to setup transmission speed, framing and mode of operation of

the serial interface. It can be congured to transmit either time strings (once per second, once per minute, or on

request with ASCII ? only), or to transmit capture strings (automatically when available, or on request). The

format of the output strings is ASCII, see the technical specications at the end of this document for details.

PTP270PEX

Date: 22nd November 2012

3

Summary of Contents for PTP270PEX

Page 1: ...MANUAL PTP270PEX IEEE 1588 Computer Clock 22nd November 2012 Meinberg Radio Clocks GmbH Co KG...

Page 2: ......

Page 3: ...7 3 4 4 Two Step or One Step 8 3 4 5 End To End E2E or Peer To Peer P2P Delay Measurements 8 3 4 6 Mode Recommendations 8 3 4 7 Message Rate Settings 8 3 4 8 ANNOUNCE Messages 9 3 4 9 SYNC FOLLOWUP M...

Page 4: ...nberg Radio Clocks GmbH Co KG Lange Wand 9 31812 Bad Pyrmont Germany Phone 49 0 52 81 93 09 0 Fax 49 0 52 81 93 09 30 Internet http www meinberg de Mail info meinberg de Date 2010 06 08 PTP270PEX Date...

Page 5: ...stalling the driver correctly 2 2 Mode of operation The on board Time Stamp Unit TSU integrated in a FPGA Field Programmable Gate Array programmable logic device monitors the data tra c on the MII int...

Page 6: ...r a continuous stream of events at a lower rate depending on the transmission speed of COM1 can be measured The format of the output string is described in the technical speci cations at the end of th...

Page 7: ...RJ45 with magnetics input signals time capture output signals signal generator PCI Express Bus register set single board computer SBC running PTP stack microcontroller reference oscillator O T CXO Tx...

Page 8: ...egrade the accuracy therefore classic layer 2 and 3 Ethernet switches with their store and forward technology are not suitable for PTP networks and should be avoided With activating the HQ Filter see...

Page 9: ...reached its nominal value the nanoseconds are reset again This procedure leads to a maximum deviation of 20 nsec of the pulse per second 1PPS of the PTP Master compared to the 1PPS of the GPS referen...

Page 10: ...hronization link 3 4 2 Network Layer 2 or Layer 3 PTP IEEE 1588 2008 o ers a number of so called mappings on di erent network communication layers For Meinberg products you can choose between running...

Page 11: ...s to be redirected and ows into the other direction A PTP slave in a sync infrastructure using E2E would in this case apply the wrong delay correction calculations until it performs the next delay mea...

Page 12: ...clock or the primary one during initialization the devices re quire to receive at least two consecutive ANNOUNCE messages Continuing our example it would take the 6 seconds to determine that the curre...

Page 13: ...the term jitter is used to describe the maximum deviation of the measured o sets around a certain mean value This time jitter of standard non PTP compliant switches can be in the range of 100 ns up to...

Page 14: ...direction Higher bandwith is implemented by using multiple lanes silmutaneously A PCI Express x16 slot for example uses sixteen lanes providing a data volume of 4 GB s For comparison when using conve...

Page 15: ...switch assigned are always available at the connector D SUB Pin Signal Signal level DIL switch 1 VCC out 5V 1 1 PPO0 out RS232 8 2 RxD in res RS232 3 TxD out res RS232 4 PPO1 out TTL 5 4 10MHz out TT...

Page 16: ...detected and the LED TX ashes whenever an outgoing PTP packet is detected by the Time Stamp Unit The 9 pin sub D connector is wired to the PTP270PEX s serial port COM0 Pin assignment can be seen in t...

Page 17: ...timecodes which are transmitted by modulating the pulse dura tion of a DC signal TTL in case of PTP270PEX see chapter IRIG standard format for details Transmission of the time code is synchronized to...

Page 18: ...7 3 IRIG Standard Format Page 15 7 3 IRIG Standard Format PTP270PEX Date 22nd November 2012 15...

Page 19: ...Page 16 7 Time codes 7 4 AFNOR Standard Format 16 Date 22nd November 2012 PTP270PEX...

Page 20: ...T Daylight Saving Time set during daylight saving time 64 Timezone O set Sign sign of TZ o set 0 1 65 TZ O set binary encoded 1 66 TZ O set binary encoded 2 O set from IRIG time to UTC time 67 TZ O se...

Page 21: ...L level ACCURACY OF PULSES depending on master oscillator TCXO OCXO LQ better than 100 nsec after synchronization and 20 minutes of operation OCXO MQ OCXO HQ better than 20 nsec after synchronization...

Page 22: ...emperature dependant dri free run 1 10 6 20 70 C 2 10 7 0 60 C Note 1 The accuracy in Hertz is based on the standard frequency of 10 MHz For example Accuracy of TCXO free run one day is 1 10 E 7 10 MH...

Page 23: ...t rungen von A1 2000 A2 2003 informationstechnischen Einrichtungen Limits and methods of measurement of radio interference characteristics of information technology equipment EN55024 1998 Grenzwerte u...

Reviews: